- 22 -
additionally color reversed, with red areas appearing cyan, greens appearing magenta and blues
appearing yellow.
5.8.2.6 RETURN
Return: Press “RET” to save all settings in D-EFFECT menu and return to the previous menu.
Press “END” to save all the menu settings and exit.
5.8.3 RS-485
-CAM ID: Select RS-485 ID from 1~255.
-ID DISPLAY: Select “ON” to display RS-485 ID or “OFF” to disable ID display function.
-BAUD RATE: This field is to set the speed at which is used to transmit instruction or information
through the RS485 port on the camera. There are six different speeds,
2400,4800,9600,19200,38400 and 57600.
-Protocol: Pelco-D, EVF-1, EVF-2, SETUP MENU.
-Return: Choose “RET” to save all settings in RS485 menu and return to the previous menu.
Choose “END” to save all the menu settings and exit.
NOTE:
RS-485 has a higher priority than control at the camera itself. If there is any conflict between local
and remote control, the camera will follow the commands from the remote site.
5.8.4 MOTION
This camera enables you to observe movements of objects in 4 different areas on the screen,
and the message “MOTION DETECTED” appears on the screen when movement is detected,
and a Motion Alarm voltage trigger output is provided at the rear of the camera; this feature
may help to improve operational efficiency. The camera detects an object’s movement by
sensing changes in the pixels displayed.
-OFF: Disables the MOTION function.
-ON:
AREA SELECT: Please select the area you would like to detect from the 4 areas in
AREA SELECT mode
AREA DISPLAY: Select “ON” to use the motion area selected in sensitivity. Select “OFF”
to disable this function.
LEFT/RIGHT: Set the coordinate of the horizontal axis 5~66.
WIDTH: Set the size of horizontal area 0~93.
TOP/BOTTOM: Set the coordinate of the vertical axis 1~60.
HEIGHT: Set the size of vertical area 0~60.
SENSITIVITY: Set the sensitivity level for the motion triggered by selecting from 0~40.
When the sensitivity value is high, motion detection sensitivity increases to sense very
small movements and vice versa.
MOTION VIEW: Select “ON” to display motion detection pixels in the live view.
RETURN: Press “RET” to save all settings in RS485 menu and return to the previous