- 23 -
5.8.5 PRIVACY
This mode masks areas you do not want to display on the screen.
-OFF: Disable the PRIVACY function.
-ON:
AREA SELECT: Please select the area you would like to hide from the 8 areas in AREA
SELECT mode
AREA DISPLAY: Select “ON” to use the area selected in the AREA SELECT. Select
“OFF” to disable this function.
LEFT/RIGHT: Set the coordinate of the horizontal axis 6~98.
WIDTH: Set the size of horizontal area 0~93.
TOP/BOTTOM: Set the coordinate of the vertical axis 0~60.
HEIGHT: Set the size of vertical area 0~61.
COLOR: Set area color. It is selectable from 0 to 15.
RETURN: Press “RET” to save all settings in RS485 menu and return to the previous
menu. Press “END” to save all the menu settings and exit.
5.8.6 SYNC
There are two SYNCHRONIZATION modes: INTERNAL and EXTERNAL LINE-LOCK. In
LINE-LOCK mode, the video signal is synchronized to the frequency of the incoming AC power.
The Line-Lock synchronization can only be used when the supply power is 24VAC 60Hz (NTSC
models) or 50Hz (PAL models).
-INT: Internal synchronization
-L/L: External line-lock synchronization
5.8.7 LANGUAGE
Select OSD language. EQ610 camera supports multiple languages including English, Japanese,
Traditional Chinese and Simplified Chinese.
5.8.8 RETURN
Press “RET” to save all settings in the SPECIAL menu and return to the previous menu.
Press “END” to save all the menu settings and exit.
5.9 ADJUST
Adjust sharpness, Blue and Red level in this section.
5.9.1 SHARPNESS
The contour of the video image becomes cleaner and more easily distinguished as the level of
SHARPNESS increases. If the level is set too high, it may affect the video image and cause noise.
The available range of level is 0~31.
5.9.2 BLUE
Adjust image’s blue level. The available range of level is 0~100.
5.9.3 RED
Adjust image’s red level. The available range of level is 0~100.