PERFORMANCE DATA
CB20-312E System Replacement Cartridge Kit EV9105-34
1- CC1E Replacement Cartridge (Gray end caps)
2- CC3E Replacement Cartridge (White end caps)
FEATURES
•Finely polishes treated water to premium quality for drinking and cooking.
•Reduces disinfectant chlorine taste & odor and chloramine taste & odor.
•Reduces dirt, rust, and other particulates such as oxidized iron, manganese, and sulfides.
•Reduces parasitic protozoan cysts such as Giardia, Entamoeba, Cryptosporidium.
•Reduces common earthy, moldy, fishy tastes and odors.
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leav- ing the system, as specified in NSF/ANSI 42 and 53.
Substance | Influent Challenge | Max. Permissible Product | Reduction | Minimum | Average |
| Concentration | Water Concentration | Requirements | Reduction | Reduction |
|
|
|
|
|
|
Aesthetic Effects |
|
|
|
|
|
|
|
|
|
|
|
Chlorine | 2.0 mg/L ± 10% |
| ≥50% |
| 97.5% |
Chloramine | 3.0 mg/L ± 10% | 0.5 mg/L |
|
| 97.5% |
Particulate, Class I |
|
|
|
|
|
particles | at least 10,000 |
| ≥85% |
| 99.1% |
0.5 to < 1µm | particles/mL |
|
|
|
|
|
|
|
|
|
|
Health Effects |
|
|
|
|
|
|
|
|
|
|
|
Cyst† | Minimum 50,000/L |
| 99.95% | 99.99% | 99.99% |
Turbidity | 11 ± 1 NTU | 0.5 NTU |
| 98.9% | 99.2% |
† Based on the use of microspheres.
* Tested using Flow rate = 5.0 gpm; Pressure = 60 psig; pH = 7.5 ±0.5; Temperature = 20˚C ±3˚C
OPERATING SPECIFICATIONS
Capacity: 60,000 gallons (227,100 L)
Pressure requirement: 20 - 100 psi (1.4 - 6.9 bar),
Temperature: 35 - 100°F
Flow Rate: 5 gpm (19 Lpm)
Operating Weight: 90 lbs.
GENERAL INSTALLATION/OPERATION/ MAINTENANCE REQUIREMENTS
•Mount system to wall studs 16" on center (spacing of mounting plate holes) on other surface capable of supporting 90 pounds when system is filled with water.
•Connect water supply to inlet of
•Connect outlet water to beverage equipment.
•After installing the CC1E cartridge, flush cartridge at full flow for 5 minutes. Install CC3E cartridges and flush system for
10 minutes.
•Replace cartridges when capacity is reached, or when flow becomes too slow, but at least every 6 months.
SPECIAL NOTICES
•Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. Installation by certified installer is recommended.
•This drinking water system must be maintained according to man- ufacturer’s instructions, including replacement of filter cartridges.
•Do not use with water that is microbiologically unsafe, or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on dis- infected waters that may contain filterable cysts.
•The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
•Check for compliance with state and local laws and regulations.
•Testing was performed under standard laboratory conditions; actual performance may vary.
EVERPURE, LLC
1040 Muirfield Drive
Hanover Park, IL 60133
TEL
Customer Service
FAX
Visit us online at: www.everpure.com
In Europe: | In Japan: |
EVERPURE EUROPE NV | EVERPURE JAPAN, INC. |
Toekomstlaan 30 | |
Belgium | Kanagawa 243 |
Tel 32 14 28 35 00 | Japan |
FAX 32 14 28 35 05 | Tel |
| FAX |
©2005 by Everpure, LLC | MR/05 146527 Rev A |