STORAGE

ENGINE

Consult the Engine Owners Manual for the manufacturer's recommendations for storage.

PUMP

The manufacturer recommends using a pump protector/winterizer, such as DP80 when storing the unit for more than 30 days and/or when freezing temperatures are expected. DP80 is availabe at the store where the pressure washer was purchased. If a pump protector/ winterizer is not available, RV antifreeze needs to be run through the pump as outlined in the steps below.

NOTE: Using a pump protector/ winterizer or RV antifreeze is to provide proper lubrication to the internal seals of the pump regardless of temperature or environment.

1.Obtain a funnel, 6 oz. (170 mL) of RV antifreeze and 16–36" (40–91cm) of garden hose with a male hose connector attached to one end.

Risk of property damage. Use only RV antifreeze. Any other antifreeze is

corrosive and can damage pump.

2.Disconnect spark plug wire.

3.Connect length of garden hose to water inlet of pump.

4.Add RV antifreeze to hose as shown.

5.Pull engine starter rope slowly several times until antifreeze comes out of high-pressure hose connection of pump.

6.Remove garden hose from water inlet of pump.

7.Reconnect spark plug wire.

PRESSURE WASHER

1.Drain all water from high pressure hose, coil it and store it in cradle of the pressure washer handle.

2.Drain all water from spray gun and wand by holding spray gun in a vertical position with nozzle end pointing down and squeezing trigger. Store in gun holder.

3.Store chemical hose so it is protected from damage.

4.If space is needed, remove handles and replace as shown.

A20116

16- ENG

Page 16
Image 16
Excell Precision XC2600 operation manual Storage, Engine Pump