Measuring TA Temperature

What you should know before using the TAT:

zMeasure only the side of the head exposed to the environment. Anything covering the area to be measured (hair, hat, wig, bandages) would insulate the area, resulting in falsely high readings.

zSlide the thermometer straight across the forehead, not down the side of the face. Midline on the forehead, the TA is about a millimeter below the skin, whereas at the side of the face, the TA is much deeper, and measuring there would result in falsely low readings.

zWhen taking the temperature behind the ear lobe (if there is perspiration on the forehead, see pg 7), first push away any hair, exposing the area. Then, tuck the thermometer on the neck under the ear lobe, in the soft conical depression, (the place where perfume might be applied).

zWait about 30 seconds before measuring the same person again to avoid excessive cooling of the skin.

zAn infant is frequently swaddled in blankets and clothing covering the neck area. Unless visibly sweaty, one measurement at the TA area is typically all that is required. Should you feel the temperature is low, then push aside any clothing or blankets covering the neck area for ~30 seconds or so, and repeat the measurement on the neck behind the ear.

Factors that may affect measurement accuracy:

The patented AHB technology in your TemporalScanner actu- ally makes two separate measurements (1) the temperature of the skin over the temporal artery, and (2) the temperature of the room. To determine the most accurate reading, it meas- ures both temperatures some 1000 times a second as you sweep the TemporalScanner across the forehead. The AHB system then calculates how much the blood has cooled down during its journey from the heart to the skin over the temporal

artery and makes allowance for this in the temperature it displays. The result is a highly accurate reading - delivered extremely fast and with no discomfort.

6

Page 6
Image 6
Exergen 2000C manual Measuring TA Temperature, Factors that may affect measurement accuracy

2000C specifications

The Exergen 2000C is a state-of-the-art temporal artery thermometer designed to provide accurate and efficient temperature readings. With its innovative technology and user-friendly features, the Exergen 2000C has become a vital tool in both clinical and home settings.

One of the key features of the Exergen 2000C is its patented infrared technology, which measures the temperature of the blood vessels located in the temporal artery, just beneath the skin of the forehead. This method allows for a non-invasive and highly accurate temperature reading, making it a safer alternative to traditional thermometers. The Exergen 2000C provides results in just seconds, ensuring quick assessments, especially critical in medical environments where time is of the essence.

The device boasts a wide temperature range, capable of measuring body temperatures from 94°F to 104°F (commonly achievable human body temperature), and even beyond for environmental readings. It comes with an intuitive display that shows the temperature readings clearly, accompanied by color-coded indicators to help interpret the results quickly. A green display signifies a normal temperature, while a yellow or red display alerts users to fever conditions.

The Exergen 2000C is designed with hygiene and user convenience in mind. Its easy-to-clean exterior and the absence of probe covers or disposables minimize cross-contamination risks, making it suitable for multiple users in a clinical setting. Additionally, the thermometer is lightweight and ergonomic, allowing for easy handling and portability.

Battery life is another significant characteristic of the Exergen 2000C, featuring long-lasting performance that reduces the need for frequent replacements. The device is equipped with an automatic shut-off feature, conserving battery life when not in use, which adds to its efficiency.

In summary, the Exergen 2000C exemplifies cutting-edge fever detection technology, providing quick, reliable, and accurate temperature assessments. Its combination of infrared measurement, ease of use, and hygienic design has made it a trusted choice for healthcare professionals and families alike. Whether in a clinic, hospital, or at home, the Exergen 2000C meets the needs of users seeking both performance and reliability in temperature measurement solutions. This makes it an essential tool in managing health effectively and swiftly.