Temperature and Humidity Ranges

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

MODE

OPERATING CONDITIONS

IF OUT OF CONDITIONS

 

Indoor temp: 18°C~32°C

- A safety device will stop continuously the

 

 

system functioning;

COOL

Indoor humidity: below 80%

- Condensation may occur on the indoor unit

 

 

Outdoor temp: -10°C~43°C(UH026/35EAV)

with risk to have either water blow off or drops

 

Outdoor temp: -15°C~43°C(UH052/70EAV)

on the floor;

 

 

 

 

Indoor temp: below 27°C

- A safety device will stop continuously the

HEAT

 

Outdoor temp: -15°C~24°C(UH026/35EAV)

system functioning;

 

 

Outdoor temp: -20°C~24°C(UH052/70EAV)

 

 

 

 

 

Indoor temp: 18°C~32°C

- A safety device will stop continuously the

 

 

system functioning;

DEHUMIDIFYING

Indoor humidity: below 80%

- Condensation may occur on the indoor unit

 

 

with risk to have either water blow off or drops

 

Outdoor temp: -10°C~43°C(UH026/35EAV)

 

Outdoor temp: -15°C~43°C(UH052/70EAV)

on the floor;

POWER SUPPLY

Single phase rated voltage

220V-240V~,50Hz

minimum and maximum limit

198V min.-264V max.

 

 

 

 

Any damage occurs out of condition specified cannot be covered by product warranty.

If the system works continuosly outside of conditions, its performace and reliability will be compromised.

Operating Recommendations

Here are a few recommendations that you should follow when using your air conditioner.

Topic

Recommendation

 

 

Heating performances

The heat pump function of the air conditioner absorbs heat from outside air and brings it

 

indoors. As the temperature of the outside air drops, the heating performance of air

 

conditioner will decrease. If you find that the room is not warm enough, using an additional

 

heating appliance is recommended.

 

 

Warm air circulation

The air conditioner circulates warm air to heat your room. It will take some time to warm the

 

air in your room entirely after the air conditioner turns on. Therefore, turn the air conditioner on

 

in advance.

 

 

Frost

When outside temperature is low but humidity is high,

 

frost may form on the outdoor unit at HEAT mode.

 

If this happens:

 

The heating operation stops.

 

The defrost mode will be triggered automatically for about 10 minutes.

 

The steam produced on the outdoor unit in the defrost mode is safe.

 

No intervention is required ; after about ten minutes,the air conditioner operates again normally.

High indoor and

If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT

outdoor temperatures

mode, the outdoor unit’s fan and compressor may stop at times. This is normal;simply wait until

 

the air conditioner switches on again.

 

 

Power failure

If a power failure occurs while the air conditioner is operating, the unit will be switched off.

 

When the power returns, the air conditioner starts up again automatically.

 

 

Protection mechanism

When the air conditioner is started immediately after being plugged in or stopped, the normal

 

operation starts up after 3 minutes for the reason of protection.

 

 

Cooling operation

The indoor unit may not get the selected fan speed such as Medium and Low under cooling

 

operation at very low outdoor temperatures for the protection of the indoor unit from ice

 

or frost.

 

During Low fan speed operation, cooling performance will be reduced. If the room does not be

 

cooled down when using Low fan speed operation, please adjust the indoor unit’s fan speed.

 

 

E-24

Page 24
Image 24
Samsung NS035NHXEA, NS070NHXEA, NS052NHXEA Temperature and Humidity Ranges, Operating Recommendations, Topic Recommendation