Periodical Checks

Periodical Checks

Type

Description

Monthly

Every 4 months

Once a year

 

 

 

 

 

 

Clean the air filter

(1)

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

Indoor unit

 

 

 

 

Thoroughly clean the heat exchanger (2)

 

 

 

 

 

 

 

 

Clean the condensate drain pipe (2)

 

 

 

 

 

 

 

 

Replace the remote control batteries

 

 

 

 

 

 

 

 

Clean the heat exchanger on the outside

 

 

 

of the unit (2)

 

 

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the inside

 

 

 

of the unit (2)

 

 

 

 

 

 

 

 

 

 

 

 

Clean the electric components with jets

 

 

 

of air (2)

 

 

 

 

 

 

Outdoor unit

 

 

 

 

Verify that all the electric components

 

 

 

 

 

 

are firmly tightened (2)

 

 

 

 

 

 

 

 

 

 

 

 

Clean the fan (2)

 

 

 

 

 

 

 

 

Verify that all the fan assembly is firmly

 

 

 

tightened (2)

 

 

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner. The frequency of these operations varies according to the characteristics of the area, the amount of dust, etc.

(1)The described operations should be performed more frequently if the area of installation is very dusty.

(2)These operations must always be performed by qualified personnel. For more detailed information, see the Installation Manual.

E-26

Page 26
Image 26
Samsung NS052NHXEA, NS035NHXEA, NS070NHXEA, NS026NHXEA manual Periodical Checks, Type, Description, Monthly, Once a year

FAQ

What are the essential periodical checks for Samsung Air Conditioner?

The essential periodical checks include cleaning the air filter, condensate drain pan, heat exchanger, condensate drain pipe, remote control batteries, heat exchanger on the outside, heat exchanger on the inside, and electric components.

How often should periodical checks be performed?

Monthly, every 4 months, and once a year, depending on the characteristics of the installation area and the amount of dust. More frequent checks are necessary for very dusty areas.

Who should perform the maintenance operations?

The described operations must always be performed by qualified personnel. Refer to the Installation Manual for more detailed information.