Exmark LAZER Z HP manual Service Interval 100 hrs, Service Interval 40 hr

Models: LAZER Z HP

1 56
Download 56 pages 58.84 Kb
Page 35
Image 35
Service Interval: 100 hrs.

5.1.10Check Spark Arrester

Kohler EFI engines only: Service Interval: 50 hours

WARNING

POTENTIAL HAZARD

Hot exhaust system components may ignite gasoline vapors even after the engine is stopped.

Hot particles exhausted during engine operation may ignite flammable materials.

WHAT CAN HAPPEN

Fire may result in personal injury or property damage.

HOW TO AVOID THE HAZARD

Do NOT refuel or run engine unless spark arrester is installed.

a)Shut off engine, remove key, and wait for all moving parts to stop.

b)Wait for muffler to cool.

c)If any breaks in the screen or welds are observed, replace arrester.

d)If plugging of the screen is observed, remove arrester and shake loose particles out of the arrester and clean screen with a wire brush (soak in solvent if necessary). Re-install arrester on exhaust outlet.

5.1.11Change engine oil:

Service Interval: 100 hrs.

NOTE: Change oil and filter after first five (5) hrs. of operation.

a)Stop engine, wait for all moving parts to stop, and remove key.

b)Drain oil while engine is warm from operation.

c)The oil drain valve is located on right hand side of engine.

Place pan under machine to catch oil and open valve with a 10 mm wrench. Allow oil to drain, then close valve.

d)Replace the oil filter every other oil change. Clean around oil filter and unscrew filter to remove. Before reinstalling new filter, apply a thin coating of oil on the surface of the rubber seal. Turn filter clockwise until rubber seal contacts the filter adapter then tighten filter an additional 2/3 to 3/4 turn.

e)Clean around oil fill cap and remove cap. Fill to specified capacity and replace cap. Use oil recommended in engine owner’s manual. DO NOT overfill.

f)Start the engine and check for leaks.

5.1.12Check hydraulic oil level:

Service Interval: 40 hr.

a)Stop engine and wait for all moving parts to stop.

b)Unhook seat latch and tilt seat up.

c)Clean area around hydraulic reservoir cap and remove cap. Oil level should be to the top of the baffle inside the tank. If not, add oil. Use only Mobil 1 15W-50 synthetic motor oil. Replace hydraulic reservoir cap and tighten until snug. Do not overtighten.

NOTE: The baffle is labeled “HOT” and “COLD”. The oil level varies with the temperature of the oil. The “HOT” level shows the level of oil when it is at 225°F (107°C). The “COLD” level shows the level of the oil when it is at 75°F (24°C). Fill to the appropriate level depending upon the temperature of the oil. For example: If the oil is about 150° F (65°C), fill to halfway between the “HOT” and “COLD” levels. If the oil is at room temperature (about 75° F (24°C)), fill only to the “COLD” level.

-30 -

Page 35
Image 35
Exmark LAZER Z HP manual Service Interval 100 hrs, Service Interval 40 hr