Page 1
Image 1
DTP T USW 333 • Setup Guide

DTP T USW 333 • Setup Guide

This guide provides instructions for an experienced installer to set up and operate the

Extron DTP T USW 333 switching video transmitter. The DTP T USW 333 transmitter switches among an analog video and two digital (HDMI) video inputs and, paired with a compatible receiver, can extend the selected signal up to 330 feet (100 m). If the selected input is HDMI, the extended video signal is HDCP-compliant.

POWER

 

1

2

3

SIG

LINK

12V

AUDIO

 

 

--A MAX

 

 

 

 

 

 

INPUTS

RGB, Y, R-Y, B-Y

HDMI

HDMI

DTP OUT

10

3

1

2

2

 

5

Installation

OVER DTP

REMOTE

RS-232

IR

CONTACT

 

TALLY

 

RS-232

RESET

Tx Rx

G

Tx Rx

1

2

3

G

1

2

3

+V

Tx Rx G

 

 

4

 

 

 

6

 

 

 

7

 

8

9

Step 1 — Mounting

Turn off or disconnect all equipment power sources and mount the transmitter as required.

Step 2 — Making Connections

Inputs

AInput 1 (RGB) connector — Connect a VGA cable between this port and the VGA output port of the analog video source.

BInput 2 and 3 (HDMI) connectors — Connect HDMI cables between these ports and the HDMI output ports of the digital video sources.

NOTE: See the LockIt® Lacing Brackets on page 3 of this guide to securely fasten the HDMI connectors to the transmitter.

CAudio input — Connect an unbalanced stereo audio source to this 3.5 mm mini stereo jack for an analog audio input. NOTE: Audio is not embedded in the HDMI signal; it is transmitted simultaneously and is present on all inputs.

Over DTP RS-232 and IR pass-through

D

RS-232 and IR connector — To pass serial or infrared data or control signals on the Over

DTP

IR

Tx Rx

 

DTP RJ-45 output, connect the controlling device to the transmitter via the RS-232 and IR

 

OVER

RS-232

RxTx G

 

captive screw connector. Connect the device to be controlled to the receiver.

 

 

 

 

DTP output to receiver

Installation ATTENTION: Do not connect this device to a computer data or telecommunications network.

EDTP RJ-45 connector — Connect the transmitter DTP Out port to the DTP In port on the receiver. Extron recommends that you terminate both cable ends in accordance with the following specifications, at a minimum:

TIA/EIA T 568B
CAT 6a, shielded

24 AWG, solid conductor

Signal LED — Lights when the unit is outputting a TMDS clock signal on the DTP output. Link LED — Lights when a valid link is established between the units on the DTP cable.

Remote control

Pins:

12345678

TP Wires

IR Device

Rx Tx Gnd

Tx Rx Gnd

RS-232 Device

 

TIA/EIA T

 

568B

Pin

Wire color

1

White-orange

 

 

2

Orange

 

 

3

White-green

 

 

4

Blue

 

 

5

White-blue

 

 

6

Green

 

 

7

White-brown

 

 

8

Brown

 

 

FRemote Contact port — If desired, for contact closure control, plug a locally-constructed contact closure control device into this 3.5 mm, 4-pole captive screw port. Momentarily short the pin for the desired input (1, 2, or 3) to G to select that input. To force an input to be always selected, leave the short in place.

NOTES:

Contact closure control overrides front panel input selections.