Package an HSA for shipment as follows:
1.Contact the Extron S3 Sales and Technical Support Hotline to obtain a return kit. Extron will send the repair kit to the location you specify.
WARNING: The flanged edges of the top of the surface
enclosure are sharp when the HSA is removed
from the table. Exercise caution when handling to prevent personal injury.
CAUTION: The flanged edges of the top of the surface enclosure are bevelled to an
1 mm). These edges are soft and can be easily nicked or bent. Exercise caution when handling and mounting the enclosure. Mishandling can damage the appearance of the enclosure.
2.Disconnect all cables, remove any AAPs, and remove the
HSA 822 from the table or desk (see “Removing and Replacing the Enclosure”, steps 1 through 8, in the “Maintenance and Modifications” section). Place the enclosure
3.Bolt the clamshell to the enclosure with two bolts and flat washers included in the return kit (see figure 25).
Figure 25. Attaching the Clamshell
4.Place the enclosure and clamshell
5.Install the rubber strips that protect the flanged edges of the top of the surface enclosure (see figure 26).
Figure 26. Installing Protective Strips
6.Release (extend) the top panel.
7.Insert the HSA 822 and the clamshell into one of the foam shells (see figure 27). Either open end of the clamshell and the open top panel will fit into the recesses in the foam.
Figure 27. Installing the Foam Shell
34 HSA 822 Hideaway Enclosure • Packaging for Shipment | HSA 822 Hideaway Enclosure • Packaging for Shipment 35 |