Extron electronic P/2 DA12 Series, P/2 DA8 user manual Mute Control, 8- Audio output wiring

Models: P/2 DA12 Series P/2 DA8

1 32
Download 32 pages 49.49 Kb
Page 21
Image 21
Figure 2-8 — Audio output wiring

Tip

L

Tip

 

 

NO GROUND HERE.

Left

Ring

Sleeve(s)

 

Sleeve(s)

Tip

R

Tip

 

 

NO GROUND HERE.

Right

Ring

 

Mute ControlEach output is assigned to a pin on the captiveL R

Left

Right

Unbalanced Stereo Output

Balanced Stereo Output

CAUTION

For unbalanced audio, connect the sleeve(s) to the center contact ground. DO NOT connect the sleeve(s) to the negative (-) contacts.

Figure 2-8 — Audio output wiring

Mute Control

The mute control provides a way to mute individual outputs, or all outputs at once. Audio and video for each output is muted simultaneously.

MUTE

A

1

3

5

7

9

11

Each output is assigned to a pin on the captive

2

4

6

8

10 12

 

screw connector. To mute any output, short its pin to the ground pin (Manual background). Multiple outputs

can be shorted at the same time. To mute all outputs at once, short pin A (all) to the ground pin.

The P/2 DA8 A model uses two 3.5 mm, 5-pole, captive screw connectors. The P/2 DA12 A model (shown above) uses two

3.5mm 4-pole connectors and two 3.5 mm 3-pole connectors. For connections to captive screw receptacles, the length of the exposed wires is critical.

NThe ideal length of stripped wire is 3/16” (5 mm):

If the stripped section of wire is longer than 3/16”, the exposed wires may touch, causing a short circuit between them.

If the stripped section of wire is shorter than 3/16”, the wires can be easily pulled out even if tightly fastened by the captive screws.

CDo not tin the wires. Tinned wire does not hold its shape and can become loose over time.

P/2 DA8 and P/2 DA12 • Installation and Operation 2-11

Page 21
Image 21
Extron electronic P/2 DA12 Series Mute Control, 8- Audio output wiring, P/2 DA8 and P/2 DA12 Installation and Operation

FAQ

What are the recommended connectors for the P/2 DA8 and P/2 DA12 amplifiers?

The P/2 DA8 A model uses two 3.5 mm, 5-pole, captive screw connectors. The P/2 DA12 A model uses two 3.5mm 4-pole connectors and two 3.5 mm 3-pole connectors.

How should I handle the stripped wire length for connections to captive screw receptacles?

The ideal length of stripped wire is 3/16 5 mm. If the stripped section of wire is longer than 3/16, the exposed wires may touch, causing a short circuit between them. If the stripped section of wire is shorter than 3/16, the wires can be easily pulled out even if tightly fastened by the captive screws.

Why should I not tin the wires when connecting to the P/2 DA8 and P/2 DA12 amplifiers?

Tinned wire does not hold its shape and can become loose over time, which can lead to connectivity issues. It is important to avoid tinning the wires for secure and long-lasting connections.