Hughes Installation

Configuration and Connections

 

 

 

 

Connecting System 4xi to Hughes-JVC DILA G1000/G10 Projectors

[System 4 model and software

version displayed here]

If the System 4xi is already configured for a Hughes-JVC DILA projector, go to step 4. If it is not set up correctly, it will be necessary to change switch settings on the System 4xi ’s Main Controller Board. Begin at Step 1 to verify the correct configuration.

1.Use the Front Panel to display the Information Menu to verify that the System 4xi is already set up for the Hughes-JVC DILA projector. Apply power to the System 4xi and do the following:

a.Press to display the MENU SELECT on the LCD screen.

b.Press or to step to Menu 8.

(See note.)

(See note.)

(See note.)

(See note.)

(Note: Information depends on System 4 setup.)

c.Press to select this menu.

}d. Press or to display the configuration. The example to the left is general, your display will show the System 4xi model name, the software version and the following information:

PRJ = HUGHES PRJ BAUD = 19200 UNIT No.= 000

HST BAUD = 9600 (value depends upon setup Menu 3)

2.Go to the procedure on page 2-3 of the System 4xi User’s Manual to remove the System 4xi cover. Then go to page 2-4 and refer to the configuration below to set up the Main Controller board. Continue with Step 3 (below) when the configuration is correct.

Config

Projector

SW1: 1-2-3-4

SW2

SW3

SW4

SW5

SW6

Prj Cable

Comm

as

 

 

 

 

 

 

 

 

Adapter

 

 

 

 

 

 

 

 

 

 

 

Hughes/JVC DILA

off-on-off-on

0

0

8

F

0

J15

26-467-01

 

 

 

 

 

 

 

 

 

 

SW3

SW2

SW4

SW5

J15

SW1

4

3

2

1

ON

3.Double-check your work and be sure the System 4xi cover is on securely.

4.Install the System 4xi in its place of operation (i.e. rack), but do not connect the power cable.

__________ Changes in some switch configurations are not detected until the power is

removed at the AC cord, and then restored.

Refer to the following connection diagrams for your Hughes projector and continue the installation. Use the UNV ADP “A” (26-467-01) provided by Extron.

Extron • System 4xi Switcher Series • User’s Manual • P/N 68-412-02 Rev. A

Page 5

Page 6
Image 6
Extron electronic P/N 68-412-02 installation instructions Version displayed here