Installation
CComposite video and audio inputs (”Video”) — Each composite video input (3B and 4B) needs one TP cable. Using TP cable, connect up to two composite video and audio sources via the PVT CV D input wallplates to 3B and 4B
CThe PoleVault™ signal transmission method is specific for PVS 204SA Plus switchers working with PVT wallplates. DO NOT connect to an MTP system. DO NOT connect to an Ethernet/LAN or data transmission system.
NDo not connect an RGB cable (cable A) to the top ports (3A and 4A) when connecting composite video cables to the lower ports (3B and 4B).
The PVS 204SA Plus is capable of receiving signals from PVT wallplates located up to 100 feet (30 m) away. The optimum distance is between 50 and 75 feet (15 and 22 m).
Cable A carries the video signals and cable B carries the audio signal, vertical sync information and 5 VDC current from the PVS to power the PVT wallplates.
The ports on the rear of the PVS 204SA Plus are color coded for input number and signal type. To ensure correct cable identification and connection during installation, a sheet of color coded cable labels is supplied. Refer to “Labeling the A/V Inputs” section in the Polevault System Installation Manual, for details.
When connecting the TP cables to the PVS 204SA Plus, do not
The cables supplied with the PoleVault system are terminated to the TIA 568A standard.
A/V output connections
DRGB video output — Connect a VGA cable to this female
EComposite (video) output — Connect a cable with an RCA connector to this female RCA jack and to the projector for composite video.
Control connection
The protocol is 9600 baud,
•The MLC provides remote control of input switching and volume.
•The IR Link accepts modulated IR signals from a remote control (e.g., the Extron IR 452 remote) enabling the remote control to be used for selecting the switcher inputs.
|
| ||
Tx Rx IR | +12V | PVS 204SA Plus |
|
|
|
| |
|
| Switcher's Rear Panel | Projector |
A B C D E |
|
+12 VDC input
NOTE If you use cable that has a drain wire, tie the drain wire to ground at both ends.
Ground ( )
B Receive (Rx) Transmit (Tx) B
ATransmit (Tx) Receive (Rx) A
50 feet (38 m) maximum
| 1A RGB | 2A RGB | 3A RGB | 4A RGB |
|
|
| AMPLIFIED OUTPUT |
| ||
N15779 |
| LISTED 17TT |
|
|
|
|
| ||||
|
|
|
|
|
| US AUDIO/VIDEO |
| DO NOT GROUND |
|
| 4/8 |
|
|
|
|
|
| APPARATUS |
| OR SHORT |
|
| |
| I |
|
|
|
|
|
| SPEAKER OUTPUTS |
|
| Ohms |
| N |
|
|
| OUTPUTS | CONTROL |
|
|
|
| |
POWER | P |
|
|
| RGB | VIDEO |
|
|
| L | R |
U |
|
|
|
|
| L | R | VOL/MUTE | |||
| T |
|
|
|
| Tx Rx IR | 12V |
|
|
| 10V |
| S |
|
|
|
|
|
|
|
|
|
|
12V | 1B RGB | 2B RGB | 3B RGB | 4B RGB | UL 2043 PLENUM RATED | A B C D | E | PAGING AUX/MIX IN |
| LINE OUT | DC VOL |
|
| /VIDEO | /VIDEO |
|
| SENSOR |
| AUDIO |
| ||
3A MAX |
|
|
|
|
|
|
|
|
|
PVS 204SA Plus Rear Panel
| ||
and power | ||
|
PROJECTOR |
|
|
| |
ON | OFF | VIDEO | 1 |
|
|
|
| LAN | PRESS TAB WITH |
|
| AUX | TWEEKER TO REMOVE | |
|
| 2 |
| |
VOLUME |
| VIDEO |
|
|
| PC | 3 |
|
|
|
|
|
|
|
|
|
|
|
CONFIG | IMAGE | 4 | Tx | Rx GROUND | Tx/IR Rx GROUND PWRSNS GROUND | +12VOUT | +V | G | SCP | Rx | Tx | GROUND | GROUND +12VIN |
| MUTE |
| |||||||||||
|
|
|
|
|
|
| A | B | E | A | B |
|
|
|
|
|
| HOST/ | PROJECTOR |
|
| SCP |
|
| MLS |
| PWR |
|
|
| CONFIG |
| COMM |
| 12V | ||||||
| MLC 104 IP PLUS |
|
|
|
|
|
|
|
|
|
|
|
MLC 104 IP Plus Front and Side Panels
NOTE You must connect a ground |
|
| |
wire between the MLC and the |
|
| |
switcher. | Rx Tx | GROUND GROUND +12VIN | |
MLC 104’s MLS and | A B | ||
| |||
|
|
Power Ports
MLS PWR
NThe PVS 204SA Plus power supply can support a typical system: for example, a PVS 204SA Plus, 4 PVT Wallplates, 2 or 4 speakers, and an MLC 104 IP Plus with an IRCM DV+.
•If an SCP 104 is used in the system, the MLC 104 Plus MUST have its own power supply.
•The PVS 204SA Plus provides sufficient power to run an MLC 104 IP Plus or any MLC 52 RS model.