Installation

CComposite video and audio inputs (”Video”) — Each composite video input (3B and 4B) needs one TP cable. Using TP cable, connect up to two composite video and audio sources via the PVT CV D input wallplates to 3B and 4B RJ-45 female connectors.

CThe PoleVaultsignal transmission method is specific for PVS 204SA Plus switchers working with PVT wallplates. DO NOT connect to an MTP system. DO NOT connect to an Ethernet/LAN or data transmission system.

NDo not connect an RGB cable (cable A) to the top ports (3A and 4A) when connecting composite video cables to the lower ports (3B and 4B).

The PVS 204SA Plus is capable of receiving signals from PVT wallplates located up to 100 feet (30 m) away. The optimum distance is between 50 and 75 feet (15 and 22 m).

Cable A carries the video signals and cable B carries the audio signal, vertical sync information and 5 VDC current from the PVS to power the PVT wallplates.

The ports on the rear of the PVS 204SA Plus are color coded for input number and signal type. To ensure correct cable identification and connection during installation, a sheet of color coded cable labels is supplied. Refer to “Labeling the A/V Inputs” section in the Polevault System Installation Manual, for details.

When connecting the TP cables to the PVS 204SA Plus, do not cross-connect the cables; connect input 1’s cable A to the RJ-45 port labeled 1A, and input 1’s cable B to the RJ-45 port labeled 1B. Likewise, connect input 2, 3, or 4‘s cable A to its corresponding numbered A port, and cable B to its B port.

RJ-45 termination must comply with the TIA/EIA T 568A or 568B wiring standards for all connectors. The same standard MUST be used at both ends of all cables. Refer to the PoleVault System Installation Manual for details.

The cables supplied with the PoleVault system are terminated to the TIA 568A standard.

A/V output connections

DRGB video output — Connect a VGA cable to this female 15-pin HD connector and to the projector for RGB video.

EComposite (video) output — Connect a cable with an RCA connector to this female RCA jack and to the projector for composite video.

Control connection

FRS-232/MLC/IR control port — The PVS switcher can be controlled via an RS­‑232 connection directly from a host computer, a control system, or a MediaLink Controller (MLC). For IR remote control connect an Extron IR Link to this port.

RS-232 connection can be used to configure the PVS switcher. Connect a cable between this port and the MLC MediaLink Controller or an optional IR Link IR signal repeater.

The protocol is 9600 baud, 8-bit, 1 stop bit, no parity, and no flow control.

The MLC provides remote control of input switching and volume.

The IR Link accepts modulated IR signals from a remote control (e.g., the Extron IR 452 remote) enabling the remote control to be used for selecting the switcher inputs.

RS-232/MLC/IR

 

Tx Rx IR

+12V

PVS 204SA Plus

 

 

 

 

 

 

Switcher's Rear Panel

Projector

A B C D E

RS-232/MLC/IR Port

+12 VDC input

NOTE If you use cable that has a drain wire, tie the drain wire to ground at both ends.

Ground ( )

B Receive (Rx) Transmit (Tx) B

ATransmit (Tx) Receive (Rx) A

50 feet (38 m) maximum

 

1A RGB

2A RGB

3A RGB

4A RGB

 

 

 

AMPLIFIED OUTPUT

 

N15779

 

LISTED 17TT

 

 

 

 

 

 

 

 

 

 

 

US AUDIO/VIDEO

 

DO NOT GROUND

 

 

4/8

 

 

 

 

 

 

APPARATUS

 

OR SHORT

 

 

 

I

 

 

 

 

 

 

SPEAKER OUTPUTS

 

 

Ohms

 

N

 

 

 

OUTPUTS

CONTROL

 

 

 

 

POWER

P

 

 

 

RGB

VIDEO

 

 

 

L

R

U

 

 

 

 

RS-232 MLC/IR

 

L

R

VOL/MUTE

 

T

 

 

 

 

Tx Rx IR

12V

 

 

 

10V

 

S

 

 

 

 

 

 

 

 

 

 

12V

1B RGB

2B RGB

3B RGB

4B RGB

UL 2043 PLENUM RATED

A B C D

E

PAGING AUX/MIX IN

 

LINE OUT

DC VOL

 

 

/VIDEO

/VIDEO

 

 

SENSOR

 

AUDIO

 

3A MAX

 

 

 

 

 

 

 

 

 

PVS 204SA Plus Rear Panel

RS-232

RS-232

and power

 

PROJECTOR

 

 

 

ON

OFF

VIDEO

1

 

 

 

 

LAN

PRESS TAB WITH

 

 

AUX

TWEEKER TO REMOVE

 

 

2

 

VOLUME

 

VIDEO

 

 

 

PC

3

 

 

 

 

 

 

 

 

 

 

 

CONFIG

IMAGE

4

Tx

Rx GROUND

Tx/IR Rx GROUND PWRSNS GROUND

+12VOUT

+V

G

SCP

Rx

Tx

GROUND

GROUND +12VIN

 

MUTE

 

 

 

 

 

 

 

 

A

B

E

A

B

 

 

 

 

 

 

HOST/

PROJECTOR

 

 

SCP

 

 

MLS

 

PWR

 

 

 

CONFIG

RS-232/IR

 

COMM

 

RS-232

12V

 

MLC 104 IP PLUS

 

 

 

 

 

 

 

 

 

 

 

MLC 104 IP Plus Front and Side Panels

NOTE You must connect a ground

 

 

wire between the MLC and the

 

 

switcher.

Rx Tx

GROUND GROUND +12VIN

MLC 104’s MLS and

A B

 

 

 

Power Ports

MLS PWR

RS-232 12V

NThe PVS 204SA Plus power supply can support a typical system: for example, a PVS 204SA Plus, 4 PVT Wallplates, 2 or 4 speakers, and an MLC 104 IP Plus with an IRCM DV+.

If an SCP 104 is used in the system, the MLC 104 Plus MUST have its own power supply.

The PVS 204SA Plus provides sufficient power to run an MLC 104 IP Plus or any MLC 52 RS model.