Configuring EDID (EDID Minder Model Only)

RGB 203 Rxi • Setup Guide (Continued)

Configuring EDID (EDID Minder Model Only)

The Extron EDID Minder ensures the resolution of the video source signals are compatible with the display devices. The RGB 203 Rxi provides 14 factory-installed EDID values that can be used. By default, the EDID value is set to a resolution of 1024x768, which will allow most source devices to boot up and provide a signal that can be displayed. Alternatively, you can record your own EDID information and use those values, or use EDID information from a monitor connected to the Local Monitor output.

User-Recorded EDID

You may also record EDID information from a specific monitor as follows:

1.Connect a display to the Local Monitor output (C) and power on the monitor and interface.

2.Turn the EDID Select dial (O) to setting 0.

3.Press and release the recessed Record button (M). The LED light will flash red slowly three times while the EDID is recorded and return to green when recording is complete.

User-Recorded EDID NOTE: This EDID will be stored in memory until deleted or overwritten.

Using Recorded EDID Values

Using Recorded EDID Values NOTE: To boot up correctly, the source device must be able to receive EDID information during the boot process.

Therefore, the interface (and the local monitor, if using pass-through EDID) must be switched on before the source is switched on.

Use factory-installed EDID information or the user-recorded EDID as follows:

1.If you have not already done so, connect the RGB 203 Rxi to the source device. Do not switch on the source device at this time.

2.Set the left front panel DIP switch (N) to the required frequency (50 or 60 Hz).

3.Set the rotary switch to the required value (see the table below). Settings 1 - E are factory installed. Setting 0 is for

user‑recorded and can only be used if a value has been stored at that location (see the previous section, "User-Recorded EDID").

Rotary Switch

Resolution

Position

 

0User-recorded EDID

1800x600

21024x768 (default)

31280x720

41280x768

51280x800

61280x1024

71360x768

81366x768

91400x1050

A1440x900

B1600x1200

C1680x1050

D1920x1080

E1920x1200

FLocal monitor pass-through

4.Power on the display device.

5.Power on the source device.

Page 3