Setup Guide —­ SW RGBHV Series Switchers

Setup Guide —­ SW RGBHV Series Switchers

This guide provides quick start instructions for an experienced installer to set up and operate the SW RGBHV and SW RGBHV A

switchers.

Installation

Step 1 — Mounting

Turn off or disconnect all equipment power sources and mount the switcher as required.

Step 2 — Inputs

Connect up to 2, 4 or 6 RGBHV, RGBS, RGsB, or RsGsBs video or component video inputs to the Input connectors.

Audio models — Connect up to 2, 4 or 6 stereo or mono audio inputs

to the 5-pin

 

captive screw

Tip

connectors.

Sleeve

 

L

RGBHV

G B

RGBS

R G B

Tip

R

Sleeve

 

Unbalanced Stereo Input

 

RGsB,

 

 

 

RsGsBs,

 

 

 

Component

R

G

B

H/HV V

H/HV V

H/HV V

Step 5 — Power

Plug a standard IEC power cord between the switcher’s power connector and a 100 VAC to 240 VAC, 50 or 60 Hz power source.

Operation

Switch mode

AUTO

Set the rear panel switch to Auto for autoswitch mode (the switcher automatically

 

switches to the highest-numbered input with a sync signal present) or Normal for

 

manual switch mode. The front panel Auto Switch Active LED lights when the

MANUAL

switcher is in autoswitch mode.

 

Switch inputs in normal switch mode

Press and release the desired input button.

Adjust audio level (audio models)

You can set the input level of audio gain or attenuation via the front panel or the Remote port to be compatible with a wide range of line level sources. Individual input audio levels can be adjusted so that there is no noticeable volume difference among sources. This function also eliminates the need for separate preamps or attenuators, when used with professional (higher

line level) and consumer (lower line level) audio equipment.

Adjust the audio from the front panel as follows:Press 1 and release.

Do not tin the wires!

Tip

L

Ring

 

 

 

Sleeve (s)

 

 

Tip

R

 

Ring

 

 

Balanced Stereo Input

1. Press and release the desired input button.

2. Press and hold the Audio Conf./Save button until the Audio Conf./ Save LED begins to blink. The approximate level is indicated by the input LEDs and the polarity by the ±dB LEDs.

1

2

Press

and hold.

Step 3 — Outputs

Connect an RGBHV, RGBS, RGsB, or RsGsBs video or component video display or other device to the Output connectors. Make connections as shown for step 3.

Audio models Connect a balanced or unbalanced stereo audio or mono audio device to the 5-pin captive screw connector.

NThe input LEDs display the approximate level of attenuation. The +dB LED indicates the level is gain (positive).

The - dB LED indicates the level is attenuation (negative).

For details about reading the displayed value, refer to the full SW RGBHV Switchers User’s Manual, available at www.extron.com.

B

CONF/SAVE

Conf/Save blinks. Release the button.

 

Tip

L

Tip

L

 

NO GROUND HERE.

Ring

 

 

 

 

Sleeve(s)

 

Sleeve(s)

 

Do not tin the wires!

Tip

R

Tip

R

NO GROUND HERE.

Ring

 

 

 

Unbalanced Stereo Output Balanced Stereo Output

CConnect the sleeves to ground (Gnd). Connecting the sleeve to a negative (-) terminal will damage the audio output circuits.

3. Press and release the >and <buttons to increase and decrease the audio level by 1 dB per push of the button, or press and hold the buttons to increase or decrease the level by 3 dB per second.

 

 

 

 

 

Press

Press

3

1

2

3

4

5

6

 

 

 

 

 

 

-dB +dB

Step 4 — Remote port

Connect a host device, such as a computer or touch panel control via RS-232, OR connect a remote contact

closure device to the switcher

5

 

1

via the 9-pin D connector for

 

 

 

 

remote control of the switcher.

 

 

 

To command a switch under

 

9

6

contact closure control,

 

momentarily short an input’s

 

Female

pin on the remote connector to

RS-232 Protocol:

9600 Baud, 8, N, 1

ground (the switcher must be in

 

normal [manual] mode).

 

Pin

RS-232

Contact

Function

 

 

 

closure

 

1

 

In #1

Input #1

2

 

TX

Transmit data (-)

3

 

RX

Receive data (+)

 

 

 

 

 

4

 

In #2

Input #2

5

 

Gnd

Gnd

Signal ground

6

 

In #3

Input #3

7

 

In #4

Input #4

8

 

In #5

Input #5

 

 

In #6

Input #6

 

 

 

 

 

Press

4. Press and release the Audio Conf./Save button to exit. The Audio and release. Conf./Save LED goes out.

4 CONF/SAVE

Extron USA - West Extron USA - East Extron Europe

Extron Asia

Extron Japan

Extron China

Extron Middle East

Headquarters

 

 

 

 

NFor complete descriptions of remote control of the switcher using the applicable Simple Instruction Set (SIS) commands and/or the Universal Switcher Control Program, refer to the full SW RGBHV Switchers User’s Manual, available at www.extron.com.

 

+800.633.9876

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

+400.883.1568

+971.4.2991800

68-648-50

+800.633.9876

Inside USA / Canada Only

Inside Europe Only

Inside Asia Only

+81.3.3511.7656 FAX

Inside China Only

+971.4.2991880 FAX

Inside USA / Canada Only

+1.919.863.1794

+31.33.453.4040

+65.6383.4400

 

+86.21.3760.1568

 

Rev. A

 

 

 

+1.714.491.1500

+1.919.863.1797 FAX

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

+86.21.3760.1566 FAX

 

04 09

+1.714.491.1517 FAX

 

© 2009 Extron Electronics. All rights reserved.

 

 

 

 

 

 

 

 

 

 

 

Page 1
Image 1
Extron electronic SW RGBHV A setup guide Power, Switch mode, Switch inputs in normal switch mode, Outputs, Remote port

SW RGBHV A, SW RGBHV specifications

Extron Electronics is renowned for its innovative signal processing solutions, and the SW RGBHV A and SW RGBHV are no exceptions. These products are designed specifically for professional video switching applications, making them ideal for use in various environments, including corporate, educational, and broadcast settings.

The SW RGBHV series excels in switching RGBHV (Red, Green, Blue, Horizontal, and Vertical sync) video signals, which are widely utilized in high-performance video setups. One of the most notable features of the SW RGBHV switches is their ability to seamlessly handle resolutions up to 1600x1200 at a refresh rate of 60 Hz. This ensures that users can maintain high-quality video output without loss of fidelity or detail.

Another prominent technology featured in the SW RGBHV A and SW RGBHV switches is the inclusion of Extron’s renowned Signal Management technology. This technology ensures that signal integrity is preserved throughout the switching process, delivering clear and crisp images. Users can experience minimal image degradation, which is essential for professional presentations and broadcasts.

The SW RGBHV switches come equipped with a variety of input and output options, allowing for flexible system integration. They typically feature multiple inputs, enabling quick and easy switching between different video sources. Additionally, the ability to distribute signals to multiple outputs makes these switches highly versatile for various applications.

In terms of control and configuration, the SW RGBHV series includes straightforward user interfaces, which can range from front panel buttons to robust remote-control capabilities. This ease of use allows operators to manage video signals efficiently, further enhancing the user experience.

Moreover, the SW RGBHV models are designed with reliability in mind. Built with durable components and advanced thermal management, these switches can withstand continuous operation in demanding environments. Extron’s commitment to quality assurance ensures that these devices are both reliable and efficient.

In conclusion, Extron’s SW RGBHV A and SW RGBHV switches stand out in the realm of professional video switching technology. Their ability to support high-resolution RGBHV signals, combined with advanced signal management features, makes them an excellent choice for any professional audio-visual setup. Their versatility, user-friendly interfaces, and reliability solidify their position as a preferred solution for users looking to optimize their video switching capabilities.