Wall-Mounting or Furniture-Mounting the TLP 1000MV

To mount the TLP 1000MV directly into a wall, follow these steps. The steps will be similar if the unit is mounted in furniture (such as a podium or table).

1.Use the template provided to mark the wall at a suitable location and cut a hole 10.06 inches (25.55 cm) wide x 6.98 inches (17.73 cm) high.

2.Unpack the TLP 1000MV and remove the faceplate.

3.Ensure all the locking arms are flush with the unit and that the TLP 1000MV can fit into the hole. If necessary, use a rasp or a coarse file to enlarge the hole.

4.Run the network and MTP cable connections inside the wall to the hole, leaving enough slack in the cables to connect them to the back of the TLP 1000MV.

5.Plug the cables into the rear panel connectors (see page 2).

Faceplate Snaps to Unit (4 plcs ea side)

Tighten Screws toWall-Mounting or Furniture-Mounting the TLP 1000MVReset ModesScreen Design and ConfigurationManual backgroundManual background

Rotate Locking Arms

zz

zz

zz

Connect the LAN port to the PoE power supply and network.

Connect the RJ-45 MTP input.

Optional: Extron recommends using the Power over Ethernet power supply provided. However, you may use the LAN port only as a network connection and connect a 12 VDC, 1.0 A power supply (not provided) to the 2-pole captive screw power input.

6.Push excess cables into the wall cavity.

7.Ensure the five locking arms (three at the top and two at the bottom) are flush with top and bottom of the TLP 1000MV and fit the touchpanel into the hole.

8.Use a Phillips head screwdriver to tighten the screws for the locking arms. As the screws tighten, the locking arms rotate behind the wall and hold the unit in place. Do not overtighten the screws as this can damage the catches or the wall.

9.If required, perform the initial calibration (see page 3).

10.Replace the faceplate by pressing the catches on the faceplate into the corresponding holes on the front of the panel.

Reset Modes

The touchpanels have four reset modes: Factory Firmware Mode, Run or Stop Events Mode, Reset All IP Settings Mode, and Reset Factory Defaults Mode. These modes can be initiated by pressing the reset button (see “TLP 1000MV Reset Buttons and LED“ for the TLP 1000MV or “Rear Panel Features“ for the TLP 1000TV). For full information about these different modes, see the TLP 1000MV and TLP 1000TV User Guide.

Screen Design and Configuration

Use Extron GUI Configurator (version 1.2 or later) to design the graphical user interface that will appear on the TouchLink panel. Use Extron Global Configurator (version 3.1 or later) to assign functions to the elements of the graphical user interface. For complete information about these software programs, see the help file of the appropriate program.

Extron USA - West

Extron USA - East

Extron Europe

Extron Asia

Extron Japan

Extron China

Extron Middle East

 

Headquarters

 

 

 

 

 

 

 

+800.633.9876

+800.633.9876

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

+400.883.1568

+971.4.2991800

 

+81.3.3511.7656 FAX

+971.4.2991880 FAX

 

Inside USA/Canada Only

Inside USA/Canada Only

Inside Europe Only

Inside Asia Only

Inside China Only

 

 

 

 

+1.714.491.1500

+1.919.863.1794

+31.33.453.4040

+65.6383.4400

 

+86.21.3760.1568

 

 

+1.714.491.1517 FAX

+1.919.863.1797 FAX

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

+86.21.3760.1566 FAX

 

 

 

 

 

 

 

 

 

 

 

© 2011 Extron Electronics All rights reserved.

www.extron.com

68-1909-50 Rev. A

 

03 11

4

Page 4
Image 4
Extron electronic setup guide TLP 1000MV and TLP 1000TV Setup Guide Cont’d, Reset Modes, Screen Design and Configuration