Skew delay problems

Installation, cont’d

Skew delay problems

CAT 5 TP cable can lead to registration errors between the red, green, and blue video signals. Pair skew can be measured with test equipment or identified by viewing a crosshatch test pattern with a critical eye to determine if either the red, green, or blue video image leads (appears to the left of) the other two video images. These images can be minimized or eliminated by one of the following methods:

Switch to Extron’s Enhanced Skew-Free A/V UTP cable.

Add a skew compensation cable equal to the length of pair skew to the receiver’s output.

Install an SEQ 100 15HD Skew Equalizer on the receiver’s video output and adjust the skew for the leading video image.

Mounting

The TP T 15HD 45 and TP T A 45 are designed to fit into a wall- mountable or floor box-mountable 45 mm mounting frame.

COMPUTER

AUDIO

 

INPUT

INPUT

 

The following application diagram illustrates one example of installing these devices.

MountingAAppendix TP T 15HD 45 and TP T A 45