Specifications, Part Numbers, Accessories, cont’d
General
Power | 100 VAC to 240 VAC, |
| 50/60 Hz, internal |
Typical | 26 watts (1/8 power [pink |
| noise] at 8 ohms) |
Quiescent | 10 watts |
Standby | <1 watt (triggered by |
| contact closure or after 1 |
| hour with no signal) |
Temperature/humidity | Storage: |
| |
| 90%, noncondensing |
| Operating: +32 to +122 °F |
| (0 to +50 °C) / 10% to 90%, |
| noncondensing |
Cooling | Convection, no vents, with |
| internal heat sinks |
Thermal dissipation |
|
Standby | <1 watt (3 BTU/hr) |
Idle | 10 watts (34 BTU/hr) |
1/8 power (pink noise) | 4 ohms (x2): 14 watts |
| 8 ohms (x2): 14 watts |
| (48 BTU/hr) |
| 70 V (XPA |
| 14 watts (48 BTU/hr) |
Protection | Clip limiting, thermal, short |
| circuit, DC output |
Indication | Limiter/Protect LED |
| indicates the onset of clip |
| limiting, thermal cycling, |
| short circuit, or DC output |
| protection |
Mounting |
|
Rack mount | Yes, with optional 1U, 9.5" |
| deep rack shelf (RSU 129, |
| |
| |
Enclosure type | Metal |
Enclosure dimensions | 1.7" H x 8.7" W x 9.5" D |
| (1U high, half rack wide) |
| (4.3 cm H x 22.1 cm W x |
| 24.1 cm D) |
Product weight | 2.5 lbs (1.1 kg) |
Shipping weight | 5 lbs (3 kg) |
Vibration | ISTA 1A in carton |
| (International Safe Transit |
| Association) |
Regulatory compliance |
|
Safety | CE, |
| UL rated for use in plenum |
| airspaces: meets UL 2043 |
| for heat and smoke release; |
| meets UL 60065, IEC 60065, |
| and BSEN 60065 for A/V |
| equipment. |
EMI/EMC | CE, CISPR 22 Class B, |
| |
| VCCI Class B |
Environmental | Complies with the |
| appropriate requirements |
| of CEC, ENERGY STAR® |
| (ENERGY STAR® qualified |
| amplifier), EU code of |
| conduct, RoHS, WEEE |
MTBF | 250,000 hours |
Warranty | 3 years parts and labor |
NAll nominal levels are at ±10%.
NSpecifications are subject to change without notice.
XTRA Series • Reference | XTRA Series • Reference |