VENTING REQUIREMENTS

Determine which venting method is best for your application. Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or floor opening around the cap.

Flexibleductworkisnotrecommended. Flexibleductwork creates back pressure and air turbulence that greatly reduces performance.

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed

FOR MORE SPECIFIC DUCTWORK INFORMATION, GO

TO PAGE 4.

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

!WARNING

Venting system MUST terminate outside the home.

DO NOT terminate the ductwork in an attic or other enclosed space.

DO NOT use 4" laundry-type wall caps.

Flexible-type ductwork is not recommended.

DO NOT obstruct the flow of combustion and ventilation air.

Failure to follow venting requirements may result in a fire.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connections must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:

National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

For residential use only.

This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever nec- essary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box).

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet.

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with any solid-state speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI- CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:InstallationWorkAndElectricalWiringMust Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire ProtectionAssociation (NFPA), and theAmerican Society for Heating, Refrigeration andAir Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not dam- age electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

!WARNING

Electrical ground is required on this rangehood.

If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for grounding.

DO NOT ground to a gas pipe.

DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.

Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded.

Failure to follow electrical requirements may result in a fire.

Version 12/04 - Page 2

Page 2
Image 2
Faber Diamante Venting Requirements, Electrical Requirements, For residential use only, Version 12/04

Diamante specifications

Faber Diamante is a standout product in the realm of premium kitchen ventilation solutions, combining advanced technology with exquisite design. This range hood is renowned for its powerful performance and aesthetic appeal, making it a perfect addition to modern kitchens.

At the heart of the Faber Diamante is its innovative suction technology. The hood features a high-efficiency blower system that ensures optimal air extraction. With a high extraction rate, it effectively removes smoke, steam, and odors, keeping the kitchen fresh and pleasant. The powerful fan operates quietly, ensuring that cooking is not interrupted by unnecessary noise, creating a serene culinary environment.

One of the significant features of the Faber Diamante is its sleek, minimalist design. It is available in various finishes, including stainless steel and glass, allowing it to complement various kitchen styles. The low-profile design adds sophistication without overwhelming the kitchen space, enhancing its overall aesthetic.

A standout characteristic of the Faber Diamante is its user-friendly control system. The hood is equipped with push-button controls or modern touch controls, enabling users to easily operate the fan speed and lighting arrangements. This intuitive interface is designed for convenience, allowing for quick adjustments while cooking.

In terms of lighting, the Faber Diamante incorporates integrated LED lights, which provide excellent illumination over the cooking surface. The energy-efficient lighting not only enhances visibility but also contributes to a contemporary aesthetic, making cooking more enjoyable.

Maintenance is also a priority with the Faber Diamante. The hood features easy-to-clean, removable filters that ensure longevity and performance. These filters capture grease and impurities effectively and can be washed in a dishwasher, making upkeep a breeze.

The Faber Diamante embodies a commitment to sustainability with energy-efficient components that adhere to modern environmental standards. This focus on energy conservation allows homeowners to enjoy high-performance ventilation without a significant energy bill.

Overall, the Faber Diamante is a fusion of functionality and style. Its powerful performance, quiet operation, sleek design, intuitive controls, and easy maintenance make it an ideal choice for homeowners seeking a premium kitchen ventilation solution that doesn't compromise on aesthetics or efficiency. Whether you're a passionate home cook or an occasional chef, the Faber Diamante is engineered to elevate your cooking experience.