DUCTED INSTALLATIONS

DUCTED INSTALLATIONS

1.For rear ducted installations, attach the rear chimney transition to the top of the rangehood (FIGURE 7) with the 4 screws provided.

2.If installing the hood with ductwork venting up thru the ceiling (not to the rear of the hood thru the wall ) , then the optional chimney covers (purchased separately) can be attached over the ductwork. Please call 508-358-5353 for instructions on attaching chimney covers.

FIGURE 7

DUCTLESS INSTALLATIONS

1.Screw the ductless grille to the top duct with 4 screws (part C using the E screws in FIGURE 8).

2.Attach the grille cover (H in FIGURE 7) using the cover screws (I in FIGURE 8).

3.Attach one charcoal filter to each end of the blower. Each charcoal filter attaches to the grid on the side of the blower. Rotate the filter clockwise to install and counterclockwise to remove (as indicated in FIGURE 9).

I

HE

C

FIGURE 8

FIGURE 9

FOR ALL INSTALLATIONS

1.Install the grease filters (as indicated in FIGURE 6)

2.Place the 4 ducting panels back onto the hood

(as indicated in FIGURE 5)

3.Turn the power supply on. Turn on blower and lights. If the rangehood does not operate, check that the circuit breaker is not tripped or the house fuse blown. If the unit still does not operate, disconnect the power supply and check that the wiring connections have been made properly.

WARRANTY & SERVICE

All Faber products are warranteed against any defect in ma- terials or workmanship for the original purchaser for a period of 1 year from the date of original purchase. This warranty covers labor and replacement parts. The warranty does not cover consumable parts such as filters and light bulbs. This warranty does not apply if this product has been subjected to faulty installation, misuse, or neglect. This warranty excludes any consequential expense or damage resulting from any use or malfunction of the product. All implied warranties are limited to the duration of this warranty.

To obtain warranty service, contact the dealer from whom you purchased the rangehood, or the local Faber distributor. If you cannot identify a local Faber distributor, contact us at (508) 358-5353 for the name of a distributor in your area.

USE AND CARE INFORMATION

This rangehood system is designed to remove smoke, cooking vapors and odors from the cooktop area.

For Best Results

Start the rangehood several minutes before cooking to develop proper airflow. Allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen.

Remote Control

The rangehood can be controlled using the enclosed remote control which has the same control layout (as indicated in FIGURE 11). The remote uses alkaline AAA type batteries. To replace the batteries, remove the cover by removing the screw and sliding off the cover (as indicated in FIGURE 10). Do not place the remote control close to heat sources.

FIGURE 10

Version 09/05 - Page 7