Faber Nova Rangehood Assembly, Tools Needed For Installation, Installation Dimensions

Models: Nova

1 12
Download 12 pages 12.34 Kb
Page 4
Image 4
TOOLS NEEDED FOR INSTALLATION

TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Flat Blade Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

INSTALLATION DIMENSIONS

The Nova chimney is adjustable and designed to meet varying ceiling heights. FIGURE 2 illustrates the standard installa- tion for the Nova which requires the canopy to be mounted 24" above the countertop. The chimney can be adjusted for ceilings between 8 feet and 9 feet.

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape

PARTS SUPPLIED FOR INSTALLATION

1 Hardware Package

1 Literature Package

PARTS NEEDED FOR INSTALLATION

2 Conduit Connectors

Power Supply Cable

Wiring Cable - Optional Remote Blower Only

1 Wall or Roof Cap

All Metal Ductwork

PLAN THE INSTALLATION

This rangehood can be installed as either ducted or ductless. The blower can be vented through the wall or ceiling. To vent through a wall, a 90° elbow is used. When installed ductless, the rangehood vents out of grates on the sides of the chimney. Ductless installations require a Ductless Kit, available from your dealer.

Min. - 1"

upper

chimney

Max. - 20"

cover

 

22"

lower

 

chimney

 

 

cover

9

1/2"

 

canopy

 

 

 

24"

19

1/4"

 

 

 

 

36"

 

 

Min. 92 1/2"

Max. 111 1/2"

cabinet

base

This rangehood can be used with an optional remote blower. If a remote blower is used, then the internal blower must be removed anddiscarded.Bothblowerscannotbeusedtogether. The remote blower connects to the rangehood using a separate wiring cable not supplied with the rangehood. The wiring cable should be installed at the same time as the ductwork.

WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY CALCULATE ALL MEASUREMENTS.

RANGEHOOD ASSEMBLY

FIGURE 2

CALCULATE THE DUCTRUN LENGTH

The ductrun should not exceed 35 feet if ducted with 3 1/4" by 10" rectangular duct and 60 equivalent feet if ducted with 9" round ductwork. Calculate the length of the ductwork by adding the equivalent feet in FIGURE 3 for each piece of duct in the system An example is given in FIGURE 4. For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. Remote blowers require 9" round duct.

45˚ Elbow

7.0 feet

90˚ Elbow

5.0 feet

90˚ Flat Elbow

12.0 feet

Wall Cap

0.0 feet

FIGURE 3

9

Feet Straight Duct

9.0 feet

2

- 90˚ Elbows

10.0 feet

Wall Cap

0.0 feet

Total System

19.0 feet

FIGURE 4

B

-

OPTIONAL BACKSPLASH

 

C

-

CANOPY

FIGURE 1

S

-

UPPER CHIMNEY

I- LOWER CHIMNEY

1- LOWER BRACKET

2- UPPER BRACKET

3- MIDDLE CHIMNEY BRACKET

!WARNING

PERSONAL INJURY HAZARD Because of the weight and size of the rangehood canopy, two or more people are needed to move and safely install the rangehood canopy.

Failure to properly lift rangehood could result in damage to the product or personal injury.

Version 11/00 - Page 4

Page 4
Image 4
Faber Nova Rangehood Assembly, Tools Needed For Installation, Installation Dimensions, Parts Supplied For Installation