WARRANTY & SERVICE

WARRANTY & SERVICE

This rangehood carries a limited warranty against manufac- turer's defects. To obtain warranty service, contact the dealer from whom you purchased the rangehood, or the local Faber distributor. If you cannot identify a local Faber distributor, contact Faber USA at (508) 358-5353 for the name of a distributor in your area.

WIRING DIAGRAMS

STANDARD INTERNAL BLOWER

*AVAILABLE REMOTE BLOWER

This rangehood uses Flourescent Lamp Type F33-15W-T8 and Starter Type S2.

* If a remote blower is used with this rangehood, current draw

must not exceed 4 amps.

USE AND CARE INFORMATION

This rangehood system is designed to remove smoke, cooking vapors and odors from the cooktop area.

Rangehood Control Panel

The control panel, located on the right-hand side under the canopy, is designed to disappear from view when not needed. To open, press upward on the front edge and release. The panel will drop into sight. To close, push upward on the bot- tom left corner of the control panel and it will slide up into the hood. The position and function of each control button is indicated in FIGURE 13.

FIGURE 13

Light On/Off Button ( L )

On/Off switch for the fluorescent light. Move the switch to "1" to turn the light ON and to "0" to turn it OFF.

Blower On/Off Button ( M )

On/Off switch for the blower. Move the switch to "1" to turn the blower ON and to "0" to turn it OFF.

Blower Speed Button ( V )

Variable speed control for blower. Move the switch to the far left for LOW Speed and to the far right for HIGH speed.

For Best Results

Start the rangehood before cooking and allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen.

Cleaning

The metal grease filters should be cleaned frequently in hot detergent solution or washed in the dishwasher. Clean painted hoods with hot soapy water. Stainless steel cleaner should be used on stainless rangehoods. Abrasives and scouring agents can scratch stainless steel finishes and should not be used to clean finished surfaces

Replacing the Fluorescent Light

To replace the fluorescent light shown in FIGURE 14, remove the diffuser clips (T) from both ends of the glass diffuser. Care- fully slide the glass diffuser all the way to the right. Lower the left end of the glass below the support flange (Z), then remove the glass by sliding it back to the left. Replace the diffuser glass by reversing these directions.

FIGURE 14