![DUCTED INSTALLATIONS](/images/new-backgrounds/77684/7768413x1.webp)
DUCTED INSTALLATIONS
1.For rear ducted installations, attach the rear chimney transition to the top of the rangehood (FIGURE 7) with the 4 screws provided.
2.If installing the hood with ductwork venting up thru the ceiling (not to the rear of the hood thru the wall ) , then the optional chimney covers (purchased separately) can be attached over the ductwork. Please call
FIGURE 7
DUCTLESS INSTALLATIONS
1.Screw the ductless grille to the top duct with 4 screws (part C using the E screws in FIGURE 8).
2.Attach the grille cover (H in FIGURE 7) using the cover screws (I in FIGURE 8).
3.Attach one charcoal filter to each end of the blower. Each charcoal filter attaches to the grid on the side of the blower. Rotate the filter clockwise to install and counterclockwise to remove (as indicated in FIGURE 9).
I
HE
C
FIGURE 8
FIGURE 9
FOR ALL INSTALLATIONS
1. Install the grease filters (as indicated in FIGURE 6)
2. Place the 4 ducting panels back onto the hood
(as indicated in FIGURE 5)
3.Turn the power supply on. Turn on blower and lights. If the rangehood does not operate, check that the circuit breaker is not tripped or the house fuse blown. If the unit still does not operate, disconnect the power supply and check that the wiring connections have been made properly.
USE AND CARE INFORMATION
This rangehood system is designed to remove smoke, cooking vapors and odors from the cooktop area.
For Best Results
Start the rangehood several minutes before cooking to develop proper airflow. Allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen.
Remote Control
The rangehood can be controlled using the enclosed remote control which has the same control layout (as indicated in FIGURE 11). The remote uses alkaline AAA type batteries. To replace the batteries, remove the cover by removing the screw and sliding off the cover (as indicated in FIGURE 10). Do not place the remote control close to heat sources.
FIGURE 10
Cleaning
Thestainlesssteelgreasefiltersshouldbecleanedfrequentlyin hot detergent solution or washed in the dishwasher. Stainless steel cleaner should be used on stainless rangehoods. Abrasives and scouring agents can scratch stainless steel finishes and should not be used to clean finished surfaces. The inside of the ducting panels (FIGURE 12) should be cleaned with a damp cloth and a neutral dish detergent. Do not use wet sponges or cloths or jets of water; do not use abrasive substances.
Grease Filter and Charcoal Filter Alarm Reset
To reset the metal grease filter alarm and the charcoal filter saturation alarm, turn off the motor and lights. Press and hold the speed 3 button for a minimum of 3 seconds until the LED's start to flash.
FIGURE 11
Version 04/08 - Page 7