With an air gap

DRAINAGE

Connect the drainage pipe incorporated into a waste disposal unit, on a drainage pipe tap or in a residual gap depending on plumbing standards in force.

It is possible to lengthen the drain pipe with material resistant to hot water and detergent. Always keep an inner diameter of at least 5/8” (1.5875 cm). Never exceed the maximum distance of 9” (22.86 cm) to the drainage piping.

Raise the drain pipe and fasten it to the lower part of the worktop. Lower it again to the drainage connection point following these instructions:

1.The connection with the drain pipe must be at least 10” (25.4 cm) from the floor.

2.The connection with the drain pipe must be no higher than 35” (88.9 cm) from the floor.

In order to make installation easier, the dishwasher includes an assembly bracket for curved drain pipes.

I M P O R T A N T

With an air gap

SinkDiswasher

Min. 10"

Max. 35"

Sink

Diswasher

Garbage

disposal unit

Min. 10"

Max. 35"

Without an air gap

Sink

Diswasher

Min. 10"

Max. 35"

Sink

Diswasher

Garbage

disposal unit

Min. 10"

Max. 35"

It is important that the bend of the drainage hose is properly anchored in the outlet to avoid falling out and the consequent risk of flooding. The (minimum and maximum) water operating pressure must fall between 0.05 and 0.1 Mpa. Make sure that the connector for the appliance’s lower pipe is properly adjusted before installing.