OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS cont.
Warning: Always unplug from electrical outlet before opening the
dust cup (container).
Note: HEPA dust cup filter must be used when operating the hand vacuum.
Using The Unit As A Hand Vacuum
1.To open the dust cup (container), push the dust cup release button and pull out the dust cup. Verify that the
HEPA dust cup filter is inside (see illustration below), then re- attach the dust cup (container) to the hand vacuum.
2.To use the Hand Vacuum with the shoulder strap, attach it to the unit as shown below.
3.To attach the oval dusting brush, crevice brush or the pet hair removal attachment to the Hand Vacuum, push attachment into the suction hole, as shown below.
4.To use the flexible hose, push the end of the hose into the suction hole, then attach the desired accessory to the other end of the flexible hose,
as shown below.
How To Operate Your Hand Vacuum
1.Hold the hand vacuum firmly in your hand by the Handle.
2.Push the On/Off Power Switch to “On” position.
3.Start vacuuming.
CAUTION: The Hand Vacuum is a very powerful unit. Make sure
that you hold it firmly, otherwise it can slip out of your hand and cause injury.
Important: This unit is equipped with a motor protective thermostat. If for some reason the vacuum cleaner should overheat, the thermostat will automatically turn the unit off. Should this occur:
• | Push the On/Off button once. |
• | Disconnect the plug from the |
| power source. |
• | Check the source of overheating |
| problem. (i.e. clogged hose or |
| filter) |
• If clogged hose or filter is found, | |
| unclog the hose and replace the |
Cleaning & Changing the HEPA Dust Cup Filter
Warning: Always unplug the unit from electrical outlet before opening
the Dust Cup (container).
Important: Do NOT use the HEPA filter cartridge without the debris screen in place.
Warning: After each Use - Always remove the Filter Debris Screen
from the HEPA Dust Cup Filter, then vigorously “TapClean” HEPA Filter until no more dust can be removed.
IMPORTANT, Please Note : The “TapClean” HEPA Dust Cup Filter & Debris Screen will stop most of the tiniest dust particles and airborne allergens from
0.3microns - many times smaller than a human hair!!! Because of this incredible filtration performance, the HEPA Dust Cup Filter will quickly accumulate, inside the white filter folds, many fine dust particles that are difficult to see but which will eventually block or reduce your suction power - if not cleaned properly. Clean the HEPA Filter and Debris Screen after each use as described in this section.
1.To open the Dust Cup (container), push button and detach the Dust Cup (container ). (Fig. 1)
2.Pull out the HEPA Dust Cup Filter. (Fig. 2)
Debris |
| |
Screen | HEPA Filter | |
| ||
Fig. 4 |
| |
5. Vigorously “TapClean” | Fig. 5 | |
the HEPA Dust Cup |
| |
Filter on a hard |
| |
surface until no more |
| |
dust is observed |
| |
falling out from |
| |
between the pleats of |
| |
the filter. (Fig. 5) |
| |
6. “TapClean” the Debris |
| |
Screen or rinse under |
| |
a faucet until clean. |
| |
(Fig. 6) Remember | Fig. 6 | |
that the Debris Screen | ||
| ||
must be completely |
| |
air dried for 24 hours |
| |
before reinstalling | Debris | |
in the vacuum. | Screen |
7.Replace the Debris Screen on the HEPA Dust Cup Filter and reinstall filter assembly in the vacuum. (not shown)
PLEASE NOTE: The white pleated filter material in the HEPA Dust Cup Filter will discolor over time
is properly "TapCleaned” after each use and suction does not return
| filters. |
• | Wait at least 45 minutes before |
| attempting to reuse the vacuum. |
• | After unit has cooled down for |
Fig. 1
Fig.2
to 100%, then we suggest that the HEPA filter
NOTE: The pet hair removal attachment is for use on upholstery, drapes and other fabric surfaces to remove lint, pet hair, etc. THE PET
HAIR REMOVAL ATTACHMENT IS NOT INTENDED TO BE USED AS A PET GROOMING DEVICE.
45 minutes, plug in the cleaner |
and push the On/Off button. The |
vacuum should start again. |
• If the vacuum still does not start, |
contact FANTOM customer service |
at |
3.Empty the dust from the Dust Cup (container). (Fig. 3)
4.Separate the debris screen from the HEPA filter cartridge by grasping the
debris screen with | Fig. 3 |
one hand and the |
|
filter frame with the |
|
other and pull apart. |
|
(Fig. 4) |
|
be “TapCleaned” vigorously until no
more dust can be removed, then rinsed under the faucet and allowed to air dry for 24 hours before refitting into the vacuum. (Fig. A) Wash once a month or when suction appears reduced.
CAUTION: The suction hole must be open, free of any obstructions at
all times. Otherwise, the motor will overheat and could become damaged.
4