OPERATING INSTRUCTIONS cont.
OPERATING INSTRUCTIONS
Emptying the Dust Cup Container
and Cleaning / Changing the
HEPA Filter & Debris Screen
Warning: Always unplug the unit from electrical outlet before opening the Dust Cup (container).
Important: Do NOT use the vacuum without the HEPA filter in place.
Warning: After each Use - Always remove the HEPA Filter and the Dust Cup Cover with the Debris Screen, then vigorously “TapClean” HEPA Filter and clean Debris Screen until no more dust can be removed.
IMPORTANT, Please Note : The “TapClean” HEPA Filter will stop most of the tiniest dust particles from
1.To remove the dust cup container, first press on the dust cup release button (1) that is located on the dust cup handle and at the same time press on the dust cup release button
(2) that is on the side of the upper housing. See illustration below. Then pull the dust cup container out.
Dust
Cup
Release
Button 1
Dust
Cup
Release
Button 2
2.To empty the dust cup container, press on the trap door release button that is on the back side of the dust cup container.
3.The HEPA filter is located underneath the dust cup container. (See illustration.) to remove the HEPA filter, hold the edges and pull it out slowly.
5.Hold the HEPA filter by the edges and vigorously “TapClean” the HEPA Filter dirty side down on a hard, flat surface until no more dust is observed falling out from between the pleats of the filter.
6.Reinstall the HEPA filter in the vacuum.
7.To Separate the Debris Screen from the dust cup, hold the dust cup in one hand and turn the dust cup cover counter clockwise and pull apart. To clean the Debris Screen, we
recommend that you rinse it under lukewarm running water to remove the dirt that accumulates
on it, but always
allow 24 hours to air dry before inserting back into the vacuum.
WARNING: Always remove the power plug from the wall outlet before assembling or removing accessories.
EXTENDING THE TELESCOPIC TUBE
Push the plastic button and pull out the smaller tube. See illustration below.
INSERTING THE TELESCOPIC TUBE INTO THE MAIN UNIT
•Insert the telescopic tube into the hole next to the dust cup handle. Make sure that the slot in the handle fits correctly into the opening. (See illustration.)
•To remove the telescopic tube, press the telescopic tube release button and pull the tube up.
ATTACHING THE FLOOR BRUSH TO THE MAIN UNIT
•Insert the floor brush into its location, in the direction of the arrow.
•To remove the floor brush from the main unit, press on the floor brush release button and pull the floor brush out.
ATTACHING THE HOSE TO THE MAIN UNIT
•Hold the end of the hose (see illustration below).
•Insert the hose into the hose connector (see arrow in illustration).