THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
Thecross-flow heatrecovery core transfers heat between the two
airstreams.It iseasily removed for cleaningor service.
MOTORS AND BLOWERS
Eachair stream has one centrifugal blower driven by a common PSC
motor.2 speed fan operation.
FILTERS
Washableair filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threadedinserts atcorners of thecabinet designed to accept the “S”
hooks and hanging straps supplied with the unit.
DEFROST
Recirculatingdamper defrost system.
CASE
Twentygauge prepaintedgalvanized steel (G60) forsuperior corrosion
resistance.Insulated to prevent exteriorcondensation. Drain connections
2 - 1/2" (12 mm)OD. Balancingports are located in the door.
WEIGHT71 lbs. (32.5 kg) SHIPPING WEIGHT 73 lbs. (33.5 kg)
ELECTRONICS
• Built-inRelay for Interfacing to furnace
OPTIONAL CONTROLS
#DHVC VentilationControl
• 2 SpeedFan setting (Low/High) • Dehumidistat
#HHSC HealthyHome System Con trol
• Automaticallyactivates the unit to deliver fresh air into your home
#DH1 Dehumidistat
• Initiateshigh speed ventilation when the indoor humidity level exceeds
theset point
OPTIONAL TIMERS
#VTC VentilationTimer Con trol - Initiates high speed ventilation
for 20, 40, or 60 minutes,(3 wire) 20 gauge wire (min.) 100'
length
OPTIONAL ACCESSORIES
#WH186 Weatherhoods, Two - 6” (150 mm) c/w 1/4” (6 mm) mesh
screen
DIMENSIONS FC155HRV inches(mm)
Model FC155HRV
Allunits conform to CSA and UL standards.
Date:___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#:_________________________________________
Submittedby: ____________________________________
*SensibleEfficiency – thermal **LatentEfficiency– moisture
Note:Effectiveness - based on temp. differential between the 2 airstreams
Efficiency– takes into account all power inputs
Performance (HVIcertified)
Netsupply air flow in cfm (L/s) against external static pressure
E.S.P
(externalstatic pressure) [cfm(L/s)]
@0.1"(25 Pa) 144(68)
@0.2"(50 Pa) 134(63)
@0.3" (75 Pa) 125(59)
@0.4" (100 Pa) 113(53)
@0.5"(125 Pa) 92(43)
@0.6" (150 Pa) 73(34)
Max.Temperature Recovery 78%
SensibleEffectiveness
@65cfm (31 L/s) 32°F(0°C) 73%
*SensibleEfficiency
@65 cfm (31 L/s) 32°F(0°C) 64%
*SensibleEfficiency
@68 cfm (32 L/s) -13°F(-25°C) 66%
VAC@ 60HZ 120
WATTS/ Low speed. 49
WATTS/ High speed 120
Amprating 1.4
2
1
20
40
60
80
100
120
140
160
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7
Static Pressure (in w.g.)
AirFlow (cfm)
2- High Speed
*1- Low speed
*Manufacturers Data
2
WARRANTY
Unitscarry a LIFETIME warranty on the heat
recoverycore and a 5 year replacement parts
warranty.
BALANCINGDAMPER
335/8"
(850mm)
STALEAIR
FROMINSIDE
FRESHAIR
FROMOUTSIDE
STALEAIR
TOOUTSIDE
FRESHAIR
TOINSIDE
143/4"
(375)
19"
(483)
*AllDuct Connections 6" (150mm)
CONDENSATEDRAINS
FILTERS
BLOWERS
*NOTE:Frontclearance of 25 inches (635 mm)
isrecommendedfor servicing unit.
RECIRCULATING
DEFROST
DAMPER
MOTOR
CORE
BALANCINGDAMPER
10