DIMENSIONS FC200HRV
inches(mm)
Model FC200HRV
Allunits conform to CSA and UL standards.
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
Thecross-flow heatrecovery core transfers heatbetween the two
airstreams.It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Eachair stream has one centrifugal blower driven by a common PSC
motor.2 speed fan operation.
FILTERS
Washableair filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threadedinserts atcorners of thecabinet designed to accept the “S”
hooks and hanging straps supplied with the unit.
DEFROST
Recirculatingdamper defrost system.
CASE
Twentygauge prepaintedgalvanized steel (G60) forsuperior corrosion
resistance.Insulated to prevent exteriorcondensation. Drain connections 2
- 1/2" (12 mm) OD. Balancing ports are located in the door.
WEIGHT 71lbs. (32.5 kg) SHIPPING WEIGHT 73 lbs (33.5 kg)
ELECTRONICS
• Built-inRelay for Interfacing to furnace
OPTIONAL CONTROLS
# DHVC VentilationControl
• 2 SpeedFan setting (Low/High) • Dehumidistat
#HHSC Healthy Home System Control
• Automaticallyactivates the unit to deliver fresh air into your home
#DH1 Dehumidistat
• Initiates high speed ventilation when the indoor humidity level exceeds
theset point
OPTIONAL TIMERS
#VTC VentilationTimer Control - Initiateshigh speed ventilation
for 20, 40, or 60 minutes,(3 wire) 20 gauge wire (min.) 100'
length
OPTIONAL ACCESSORIES
#WH186 Weatherhoods, Two -6” (150 mm) c/w 1/4” (6 mm) mesh
screen
Date:___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#:_________________________________________
Submittedby: ____________________________________
*SensibleEfficiency – thermal **LatentEfficiency– moisture
Note:Effectiveness - based on temp. differential between the 2 airstreams
Efficiency– takes into account all power inputs
Performance (HVIcertified)
Netsupply air flow in cfm (L/s) against external static pressure
E.S.P
(externalstatic pressure) [cfm(L/s)]
@0.1" (25 Pa) 207(97)
@0.2"(50 Pa) 200(94)
@0.3" (75 Pa) 184(87)
@0.4" (100 Pa) 171(80)
@0.5"(125 Pa) 152(71)
@0.6"(150 Pa) 130(61)
@0.7" (175 Pa) 116(55)
@0.8" (200 Pa) 86(40)
Max.Temperature Recovery 74%
SensibleEffectiveness
@66 cfm (31 L/s) 32°F(0°C) 74%
*SensibleEfficiency
@66 cfm (31 L/s) 32°F(0°C) 64%
*SensibleEfficiency
@109 cfm (51 L/s) -13°F(-25°C) 62%
VAC@ 60HZ 120
WATTS/ Low speed. 87
WATTS/ High speed 164
Amprating 1.4
LOW
Hi1
Hi2
Hi3
40
60
80
100
120
140
160
180
200
220
0 0.1 0.2 0.3 0.4 0.5 0.6 0. 7 0.8 0.9
Static Pressure (in w.g.)
AirFlow (cfm)
Hi3 - High Speed
Hi2 - Medium High Speed
Hi1- M edium Speed
Low-Low s peed
*Manufacturers Data
WARRANTY
Unitscarry a LIFETIME warranty on the heat
recoverycore and a 5 year replacement parts
warranty.
BALANCINGDAMPER
335/8"
(850mm)
STALEAIR
FROMINSIDE
FRESHAIR
FROMOUTSIDE
STALEAIR
TOOUTSIDE
FRESHAIR
TOINSIDE
143/4"
(375mm)
19"
(483mm)
*AllDuct Connections 6" (150 mm)
CONDENSATEDRAINS
FILTERS
BLOWERS
*NOTE:Front
clearance
of25inches
(635mm)
isrecommended
forservicingunit.
RECIRCULATING
DEFROST
DAMPER
MOTOR
CORE
BALANCINGDAMPER
AllDuct Connections 6” (160 mm)
INSTALLERSELECTABLE HIGH SPEED SETTINGS
AdjustableDIP switches are located on the circuit board. Hi3 is
thefactory setting. Refer to the Operation and Installation
manualfor the adjustment instructions.
11