12
STALEAIR
TOOUTSIDE
FRESHAIR
FROMOUTSIDE
STALEAIR
FROMINSIDE FRESH AIR
TOINSIDE
14
3
/4"
(375)
19"
(483)
*AllDuctConnections6"(150mm)
FILTERS
BLOWERS
*NOTE: Frontclearance
of25 inches(635mm)
isrecommended
for servicingunit.
MOTOR
ENTHALPICCORE
33-5/8"
(850)
BALANCING
DAMPER
BALANCING
DAMPER
CORE
Model FC150ERV
DIMENSIONS FC150ERV inches(mm)
Date:___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#:_________________________________________
Submittedby: ____________________________________
Allunits conform to CSA and UL
standards.
Static Pressure (in w.g.)
AirFlow(cfm)
20
40
60
80
100
120
140
160
180
200
220
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
1-Low s peed
2- High Speed
2
1
*SensibleEfficiency – thermal **Latent Efficiency – moisture
Note:Effectiveness - based on temp. differential between the 2 airstreams
Efficiency– takes into account all power inputs
Performance
Netsupply air flow in cfm (L/s) against external static pressure
E.S.P
(externalstatic pressure) [cfm(L/s)]
@0.1" (25 Pa) 151(71)
@0.2"(50 Pa) 140(66)
@0.3" (75 Pa) 131(62)
@0.4"(100 Pa) 123(58)
@0.5" (125 Pa) 107(50)
@0.6" (150 Pa) 98(46)
@0.7" (175 Pa) 81(38)
@0.8" (200 Pa) 60(28)
SensibleEffectiveness
@64 cfm (30 L/s) 32°F(0°C) 81%
*SensibleEfficiency
@64cfm (30 L/s) 32°F(0°C) 69%
TotalEfficiency 50%
@64 cfm (30L/s) 95°F(35°C) 47%
VAC@ 60HZ 120
WATTS/ Low speed. 63
WATTS/ High speed 173
Amprating 1.4
LATENT RECOVERY/MOISTURE TRANSFER CORE
Thecross-flow energyrecovery core transfers heat and water vapor
betweenthe twoairstreams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Eachair stream has one centrifugal blower driven by a common PSC
motor.5 speed fan operation.
FILTERS
Washableair filters in exhaust and supply air streams.
MOUNTING THE ERV
Four threadedinserts at corners of case designed to accept the "S" hooks
andhanging straps supplied with the unit.
CASE
Twentygauge prepaintedgalvanized steel (G60) for superior corrosion
resistance.Insulated to prevent exteriorcondensation. Door balancing
ports.
WEIGHT 75 lbs. (34Kg) SHIPPING WEIGHT 77lbs. (35Kg)
ELECTRONICS
•Built-in Relay for Interfacing to furnace
OPTIONAL CONTROLS
#D HVC VentilationControl
• 2 SpeedFan setting (Low/High) • Dehumidistat
#HHSC HealthyHome System Control
• Automaticallyactivates the unit to deliver fresh air into your home
#DH1 Dehumidistat
• Initiates high speed ventilation when the indoor humidity level exceeds
theset point
OPTIONAL TIMERS
#VTC VentilationTimer Control - Initiateshigh speed ventilation
for 20, 40, or 60 minutes,(3 wire) 20 gauge wire (min.) 100'
length
OPTIONAL ACCESSORIES
#WH186 Weatherhoods, Two - 6” (150 mm) c/w 1/4” (6 mm) mesh
screen
WARRANTY
Unitscarry a five (5) year warranty
onthe enthalpic (ERV) core and a 5
yearreplacement parts warranty.