THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
Thecross-flow heatrecovery core transfers heatbetween the two
airstreams.It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Eachair stream has one centrifugal blower driven by a common PSC
motor.The unit has a 2 speed fan operation.
FILTERS
Washableair filters in exhaust andsupply air streams.
MOUNTING THE HRV
Four threadedinserts atcorners of thecabinet designed to accept the “S”
hooks and hanging straps supplied with the unit.
DEFROST
Recirculatingdefrost syst em.
CASE
Twentygauge prepaintedgalvanized steel (G60) forsuperior corrosion
resistance.Insulated to prevent exteriorcondensation. Drain connections
2 - 1/2" (12 mm)OD.
WEIGHT 52lbs. ( 23.6 kg) SHIPPINGWEIGHT 56 lbs (25.4 kg)
ELECTRONICS
• Built-in Relay for Interfacing to furnace
OPTIONAL CONTROLS
#DHVC VentilationControl
• 2 SpeedFan setting (Low/High) • Dehumidistat
#HHSC HealthyHome System Con trol
• Automaticallyactivates the unit to deliver fresh air into your home
#DH1 Dehumidistat
• Initiateshigh speed ventilation when the indoor humidity level exceeds
theset point
OPTIONAL TIMERS
#VTC VentilationTimer Control - Initiateshigh speed ventilation
for 20, 40, or 60 minutes,(3 wire) 20 gauge wire (min.) 100'
length
OPTIONAL ACCESSORIES
#WH185 Weatherhoods, Two - 5” (125 mm) c/w 1/4” (6 mm) mesh
screen
WARRANTY
Unitscarry a LIFETIME warranty on the
heatrecovery core and a 5 year
replacementparts warranty.
Allunits conform to CSA and UL standards.
Date:___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#:_________________________________________
Submittedby: ____________________________________
*SensibleEfficiency – thermal **Latent Efficiency – moisture
Note:Effectiveness - based on temp. differential between the 2 airstreams
Efficiency– takes into account all power inputs
Performance (HVIcertified)
Netsupply air flow in cfm (L/s) against external static pressure
E.S.P
(externalstatic pressure) [cfm(L/s)]
@0.1"(25 Pa) 76(36)
@0.2"(50 Pa) 73(34)
@0.3" (75 Pa) 70(33)
@0.4" (100 Pa) 66(31)
@0.5" (125 Pa) 60(29)
Max.Temperature Recovery 88%
SensibleEffectiveness
@60 cfm (28 L/s) 32°F(0°C) 88%
*SensibleEfficiency
@60 cfm (28 L/s) 32°F(0°C) 75%
*SensibleEfficiency
@61 cfm (29 L/s) -13°F(-25°C) 68%
VAC@ 60HZ 120
WATTS/ Low speed. 59
WATTS/ High speed 150
Amprating 0.9
Static Pressure (in w.g.)
AirFlow(cfm)
Speed2
Speed1
20
30
40
50
60
70
0 0.1 0.2 0.3 0.4 0.5 0.6
80
1- Low Speed
2-High Speed
Removable
HeatRecovery
Core
DrainPan
Drainspout
FRONT TOP
minimum
18inches (459 mm)
requiredfor
serviceaccess
Threaded
inserts(4)
atcorners
SUPPLY
Freshair
fromoutside
5"round collar
SUPPLY
Freshair
tobuilding
6"round
(conv.tooval)
collar
EXHAUST
StaleAir
tooutside
5"round collar
EXHAUST
Returnair
frombuilding
6"round (conv.to oval)
collar
18.5"
(470mm)
18.5"
(470mm)
16"
(406mm)
SIDE
Hanging
straps(4)
24.5"
(622mm)
DIMENSIONS FC95HRV inches(mm)
Model FC95HRV
8