3.Drill a 1/8” hole into the body of the UV-1500C at the marked locations. (See Figure 8)

4.Secure the extension covers the UV-1500C body with the supplied metal screws (See Figure 9 & 10).

5.Remove the two rubber feet on the side of the extension cover from bottom of unit to give necessary clearance for ceiling mount. (See Figure 11)

Figure 8

 

 

 

Figure 11

Figure 9

Figure 10

 

6.Before hard wiring the UV-1500C, an electrical conduit box must be installed. Remove the wire cover in the back of the unit. Uninstall the wire nuts and discard the power cord. (See Figure 12).

7.Mount the supplied electrical conduit box over the power wires and secure with the supplied mounting screws. (See Figure 13)

Figure 12

Figure 13

8.Locate and remove the ceiling tile where the UV-1500C will be mounted.

9.Install eyelet screws or other appropriate anchors into the ceiling joists above the location where the will be installed. If installing the UV-1500C into 4-foot by 2-foot title grid, install an additional suspended ceiling tee bracket into the ceiling grid to form a 2-foot by 2-foot title location. (See Figure 14)

10.Install the UV-1500C into the suspended ceiling grid then install support wires (16 gauge wire) or other suspended ceiling support method between the installed ceiling anchors and the four mounting brackets on the back of the UV-1500C. (See Figure 15)

Figure 14

Support Wire

Figure 15

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door open. Avoid touching the glass portion of the lamp with your hands.