FS-8700-59 Canatal Sachnet

 

 

Driver Manual

 

 

 

 

 

 

 

 

Series

Table

Data Format

Max

Read

Description

Notes

 

5

10

CANA_PERCENT

4

R

Analog Outputs

 

 

5

11

CANA_BYTE

48

RW

Alarm Status

 

 

5

12

CANA_BYTE

3

R

Control Status

 

 

5

13

CANA_BCD_CODED

7

RW

Time

 

 

5

14

CANA_BYTE

4

R

Staged Output Status

 

 

5

15

CANA_WORD

17

RW

Accumulating Run Time

 

 

5

15

CANA_BYTE

1

RW

Machine Remote Control

 

 

 

 

 

 

 

 

 

 

6

4

CANA_BCD_CODED

6

R

FirmWare

 

 

6

5

CANA_BYTE

75

RW

Keycode

Mixed

 

6

6

CANA_SWAP_INT

7

R

Sensor Reading

 

 

6

7

CANA_BCD_4

3

RW

Security

 

 

6

8

CANA_BYTE

84

RW

Time Schedule

 

 

6

9

CANA_BYTE

16

R

Switched Output

 

 

6

10

CANA_PERCENT

4

R

Analog Outputs

 

 

6

11

CANA_BYTE

241

RW

Alarm Status

 

 

6

12

CANA_BYTE

10

R

Control Status

 

 

6

13

CANA_BCD_CODED

7

RW

Time

 

 

6

14

CANA_BYTE

4

R

Staged Output Status

 

 

6

15

CANA_SWAP_INT

64

RW

Accumulating Run Time

 

 

6

16

CANA_BYTE

1

RW

Machine Remote Control

 

 

6

17

CANA_BYTE

7

RW

KeyCode2

Mixed

 

 

 

 

 

 

 

 

 

9

4

CANA_BCD_CODED

6

R

FirmWare

 

 

9

5

CANA_BYTE

75

RW

Keycode

Mixed

 

9

6

CANA_SWAP_INT

7

R

Sensor Reading

 

 

9

7

CANA_BCD_4

3

RW

Security

 

 

9

8

CANA_BYTE

84

RW

Time Schedule

 

 

9

9

CANA_BYTE

16

R

Switched Output

 

 

9

10

CANA_PERCENT

4

R

Analog Outputs

 

 

9

11

CANA_BYTE

121

RW

Alarm Status

 

 

9

12

CANA_BYTE

10

R

Control Status

 

 

9

13

CANA_BCD_CODED

7

RW

Time

 

 

9

14

CANA_BYTE

4

R

Staged Output Status

 

 

9

15

CANA_SWAP_INT

64

RW

Accumulating Run Time

 

 

9

16

CANA_BYTE

1

RW

Machine Remote Control

 

 

9

17

CANA_BYTE

7

RW

KeyCode2

Mixed

 

 

 

 

 

 

 

 

 

Mixed Data Formats: The drivers uses the Data Format listed in the above table as the default. If you wish to poll data of different data types from one table then you will need at least two map descriptors for that table. Example 2 in section 4.4.4 illustrates this. You will use the cana_format parameter in the map descriptor to over-ride the default. Read the Canatal product literature, determine the table storage format of the point(s) of interest and over-ride the default format in your map descriptor. Note that map descriptors that include a range of points of mixed data formats will cause unexpected results.