FS-8700-64 ATMI ACM

Page 14 of 22

 

 

The driver stores the following data.

 

 

 

 

 

 

 

 

Array

Contents

 

 

 

Element

 

 

 

 

(offset

 

 

 

 

dependent

 

 

 

 

on port

 

 

 

 

number)

 

 

 

 

0

 

Not Used

 

 

1

ATMI_STAT_SCAN1

FieldServer Tech Support diagnostic.

 

 

2

 

FieldServer Tech Support diagnostic.

 

 

 

 

Screen decoding abandoned because

 

 

 

 

the area number was unintelligible (>

 

 

 

ATMI_STAT_DECODE1

80)

 

 

3

 

Driver has found an end-of-screen

 

 

 

ATMI_STAT_FINIS

identifier.

 

 

4

 

FieldServer Tech Support diagnostic.

 

 

 

 

The line number was unintelligible ( >

 

 

 

ATMI_STAT_COLLECT1

25 ).

 

 

5

 

FieldServer Tech Support diagnostic.

 

 

 

 

The collection function returned an

 

 

 

ATMI_STAT_COLLECT2

error. Row or Column were inconsistent.

 

 

6

 

FieldServer Tech Support diagnostic. A

 

 

 

 

start-of-screen identifier was found

 

 

 

ATMI_STAT_COLLECT3

before whilst processing screen data.

 

 

7

 

Equivalent to the error light on the ATMI

 

 

 

ATMI_STAT_ERRORLIGHT

ZD80 processor.

 

 

8

 

A start of screen identifier has been

 

 

 

ATMI_STAT_START

found.

 

 

9

 

A new line of screen data has been

 

 

 

ATMI_STAT_LF

identified.

 

 

10

 

FieldServer Tech Support diagnostic.

 

 

 

 

The collection function returned an

 

 

 

ATMI_STAT_ERRORLIGHT1

error. Row was inconsistent.

 

 

11

 

FieldServer Tech Support diagnostic.

 

 

 

 

The collection function returned an

 

 

 

ATMI_STAT_ERRORLIGHT2

error. Column was inconsistent.

 

 

12

 

A time greater than the port timeout has

 

 

 

 

elapsed since the last complete screen

 

 

 

ATMI_STAT_TIMEOUT

full of data.

 

 

13

 

A time greater than the port’s inter

 

 

 

 

character timeout (ic_timeout) has

 

 

 

 

passed since the driver last received a

 

 

 

ATMI_STAT_ICTIMEOUT

new character from the ACM unit.

 

 

14

 

The number of ACM data byte

 

 

 

ATMI_STAT_BYTECOUNT

processed

 

 

15

 

The number of streaming (buffer

 

 

 

ATMI_STAT_STREAMING

overflow) errors.

 

 

16

 

When processing the most recent

 

 

 

 

message, at least one map descriptor

 

 

 

ATMI_STAT_STORE_LASTMAPDESCP

was found with which to store data.

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Page 15
Image 15
FieldServer FS-8700-64 instruction manual Contents

FS-8700-64 specifications

The FieldServer FS-8700-64 is a powerful and versatile communication gateway designed to facilitate the integration of various building automation and industrial control networks. It serves as a bridge between disparate systems, enabling seamless interoperability and enhanced data exchange among multiple protocols. This makes the FS-8700-64 an essential tool for modern facilities seeking to optimize operations and improve efficiency.

One of the standout features of the FS-8700-64 is its support for a wide array of communication protocols. This includes popular standards such as BACnet, Modbus, LonWorks, and more. Such compatibility allows users to connect legacy systems with modern technology seamlessly. The device can convert data formats, ensuring that information flows smoothly between systems that otherwise would have been isolated.

The FS-8700-64 is equipped with a robust processing unit that guarantees high performance and reliability. This allows it to handle large volumes of data in real-time, making it suitable for complex environments where fast and accurate information exchange is critical. Furthermore, it features extensive memory capacity, enabling users to store significant amounts of data for both immediate analysis and historical reference.

In addition to its hardware capabilities, the FS-8700-64 leverages advanced software technologies to enhance functionality. The device’s configuration can be managed through an intuitive web interface, simplifying setup and ongoing maintenance. Users can easily customize settings, monitor system performance, and troubleshoot issues without requiring specialized expertise.

The FS-8700-64 also emphasizes security, a vital consideration in today’s interconnected landscape. The device is designed with features to safeguard communications against unauthorized access and cyber threats, ensuring a secure operating environment for sensitive data.

Another significant advantage of the FS-8700-64 is its scalability. The modularity of the device allows for easy upgrades and expansions to meet growing operational demands. As businesses evolve, the FS-8700-64 can adapt, ensuring continued performance and functionality well into the future.

In summary, the FieldServer FS-8700-64 is an indispensable communication gateway for organizations looking to streamline their building automation and industrial control systems. With its extensive protocol support, robust performance, user-friendly software, and strong security features, it stands as a leading choice for achieving efficient and integrated operations across various environments.