ATMI:#3 Error. Incoming data on port=%d is being abandoned. MapDesc rqd.

No map descriptors were found on the indicated port with which the driver could store the incoming data. Change the CSV file and reset the FieldServer. This message is only printed once even if the error occurs more than once.

ATMI:#6 FYI. The mapDesc called <%s> is too short.

Edit the CSV file. Increase the length of the map desc and reset the FieldServer.

ATMI:#5 FYI. You could have used a mapDesc called <%s> to expose diagnostic info. No action I s required. Read section 6.3 for more information..

*ATMI:#9 Err. Mapdesc=<%s> data array=<%s> too short

The data array associated with the map descriptor being used to store ‘current port‘ data is too short. Increase the length of the data array (not the length of the map descriptor) to at least 17. For malfunction map descriptors set the length to at least 100. Edit the CSV file, make the change and then reset the bridge.

*ATMI:#10 Err. Mapdesc=<%s> data array=<%s> too short

The data array defined by the DA_Bit_Name parameter associated with the map descriptor being used to store ‘current port‘ data is too short. Increase the length of the data array (not the length of the map descriptor) to at least 90. Edit the CSV file, make the change and then reset the bridge.

*ATMI:#11 Err. Mapdesc=<%s> data array=<%s> too short

The data array defined by the DA_Byte_Name parameter associated with the map descriptor being used to store ‘current port‘ data is too short. Increase the length of the data array (not the length of the map descriptor) to at least 90. Edit the CSV file, make the change and then reset the bridge.

2Mapdesc=<%s> Gas#=%d. Too big.The driver is trying to store the the current port’s gas data. A Gas number larger than 16 has been found. It cannot be stored and has been discarded. Your ACM may need re-configuring. Changing the driver configuration will not correct this problem. Report this error to ATMI.*These messages are produce once only and then suppressed so that they do not fill the error log every by being re-printed every time a new message is processed. A consequence of this, is that, if the error occurs more than once in a configuration, the second and subsequent occurrences will not be revealed until the first has been corrected.

*ATMI:#13 Error. Illegal Map Descriptor length - defaulting to 1

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Page 17
Image 17
FieldServer instruction manual FS-8700-64 Atmi ACM

FS-8700-64 specifications

The FieldServer FS-8700-64 is a powerful and versatile communication gateway designed to facilitate the integration of various building automation and industrial control networks. It serves as a bridge between disparate systems, enabling seamless interoperability and enhanced data exchange among multiple protocols. This makes the FS-8700-64 an essential tool for modern facilities seeking to optimize operations and improve efficiency.

One of the standout features of the FS-8700-64 is its support for a wide array of communication protocols. This includes popular standards such as BACnet, Modbus, LonWorks, and more. Such compatibility allows users to connect legacy systems with modern technology seamlessly. The device can convert data formats, ensuring that information flows smoothly between systems that otherwise would have been isolated.

The FS-8700-64 is equipped with a robust processing unit that guarantees high performance and reliability. This allows it to handle large volumes of data in real-time, making it suitable for complex environments where fast and accurate information exchange is critical. Furthermore, it features extensive memory capacity, enabling users to store significant amounts of data for both immediate analysis and historical reference.

In addition to its hardware capabilities, the FS-8700-64 leverages advanced software technologies to enhance functionality. The device’s configuration can be managed through an intuitive web interface, simplifying setup and ongoing maintenance. Users can easily customize settings, monitor system performance, and troubleshoot issues without requiring specialized expertise.

The FS-8700-64 also emphasizes security, a vital consideration in today’s interconnected landscape. The device is designed with features to safeguard communications against unauthorized access and cyber threats, ensuring a secure operating environment for sensitive data.

Another significant advantage of the FS-8700-64 is its scalability. The modularity of the device allows for easy upgrades and expansions to meet growing operational demands. As businesses evolve, the FS-8700-64 can adapt, ensuring continued performance and functionality well into the future.

In summary, the FieldServer FS-8700-64 is an indispensable communication gateway for organizations looking to streamline their building automation and industrial control systems. With its extensive protocol support, robust performance, user-friendly software, and strong security features, it stands as a leading choice for achieving efficient and integrated operations across various environments.