3.2. Fastening the Heater on a Wall

3.2. Fastening the Heater on a Wall

1.Fasten the wall-mounting rack on the wall byusing the screws which come with the rack. Observe the minimum safety distances given in table 1 and fig. 5. The fastening of the mounting rack is shown in figure 6.

NOTE! There should be a support, e.g. a board, behind the panel, so that the fastening screws can be screwed into a thicker wooden material than the panel. If there are no boards behind the panel, the boards can also be fastened on the panel. See figure 4.

2.Lift the heater onto the rack on the wall so that the connecting box switches are easily accessible.

3.The steam distributor / rock guard must always be fastened on the wall side of the heater. To turn the distributor / guard, loosen the fastening screw and then turn it. See figure 9.

3.3.Installation capillary tubing and bulb

Before hooking up electrical wires to junction box of heater, remove capillary tubing and bulb from junction box and bring up wall to left or right side of heater. Cover tubing with wooden molding provided, coil up excess tubing, and place under heater close to floor.

Be sure to cover thermostat bulb with protective metal cover by threading bulb through holes in cover, and fasten bulb cover to wall with screws provided. Also, take care when nailing protective wood strips over capillary tubing, so that nails do not puncture tubing. If punctured, entire thermostat must be replaced. See figure 7.

3.4.Safety Railing

If a safety railing is built around the heater, the minimum distances given in fig. 8 must be observed.

Figure 6. Location of the mounting rack of the heater

Figure 7. Installation of the thermostat sensor

Figure 8.

Safety railing of the heater

Figure 9.

Connections and parts of the heater