Firex COQ3, COQ6 How to Install Your CO Alarm cont, How to Operate Your CO Alarm, Service

Models: COQ3 COQ6

1 8
Download 8 pages 9.77 Kb
Page 5
Image 5
How to Install Your CO Alarm cont.

How to Install Your CO Alarm cont.

11.Firmly PRESS AND RELEASE THE RESET/TEST button. See Figure 4. The alarm should sound a short tone. The amber SERVICE light will turn on, and the CO alarm will go through its test cycle. The red LED will flash, and the alarm will beep four times fol- lowed by 5 seconds of silence and then repeat the cycle. After the test cycle, amber SERVICE light will turn off, and the green POWER light will remain lighted which means that the CO alarm is operating properly.

PRESS

IN, HOLD,

AND

RELEASE

TO

RESET

AND/OR

TEST.

FIGURE 4

12.If the alarm is interconnected to other CO alarms, press and hold the RESET/TEST button until the red light turns on. Other interconnected alarms will also beep four times followed by 5 seconds of silence. The red ALARM light on other alarms will not light during this test.

13.Two self-adhesive labels have been provided with instructions indicating what to do if the alarm sounds. Add the phone numbers of your emergency services provider and a qualified technician to each label. Place one of the labels in a visi- ble area next to the alarm, and place the other label near a source of fresh air which will be used as a gathering place if the alarm sounds.

How to Operate Your CO Alarm

This carbon monoxide alarm has been evaluated by UL and meets the applicable UL standards and requirements.

This CO alarm has a three light and sound alarm system:

CARBON MONOXIDE ALARM

ON

SERVICE

ALARM:

 

 

MOVE TO FRESH AIR

On

(Power on/operating)

Service

(Problem with Alarm)

Alarm

(Dangerous CO levels)

Low Battery

(For COQ6 only)

Green indicator constantly ON indicates unit is receiving AC power.

Amber indicator flashing and alarm horn beeping every thirty seconds indicates “Unit Fault.” Press and release the TEST/RESET button. If the alarm returns to displaying the fault signal, the CO alarm is not operating properly. REPLACE THE CO ALARM IMMEDIATELY. SEE THE WARRANTY INFORMATION AT THE END OF THIS MANUAL.

Red indicator flashes and alarm horn sounds four fast beeps and then is quiet for 5 seconds.

The unit will emit a chirp once every 30 seconds when the battery is low and needs to be replaced.

When the CO concentration builds to a level that is equal to 70 ppm or greater for the duration identified within the standard, the following will occur:

The ALARM light and sound signals will activate. See the “What To Do If Your Alarm Sounds” section of this manual for important action steps to be taken.

If you wish to press the TEST/RESET button during this time, the alarm will become quiet for approximately four minutes. The ALARM signals will be reenergized within 4 minutes from the time the reset button is pressed if the concentration of carbon monoxide surrounding the alarm remains at 70 ppm or greater.

The alarm will remain silent if the CO concentration has decreased below the alarm level of the standard. See the “What To Do If Your Alarm Sounds” section of this manual for important action steps to be taken.

The alarm will continue for as long as the condition exists.

The alarm will not permanently end its ALARM mode until the concentration of CO has been reduced to a safe level.

5

Page 5
Image 5
Firex COQ3, COQ6 owner manual How to Install Your CO Alarm cont, How to Operate Your CO Alarm, Service