!WARNING
This unit cannot be used in recreational vehicle applications.
How to Install Your CO Alarm
!WARNING
ELECTRICAL SHOCK HAZARD. Turn off power at the main fuse box or cir- cuit breaker by removing the fuse or switching the circuit breaker to the OFF position.
!CAUTION
Check local codes for specific mounting requirements in your area.
Once you have decided the best place to install the CO alarm(s), follow these steps:
1.From back of CO alarm, slide mounting plate and lift from base. See Figure 1.
2.For Model COQ6 only: Connect new
3. Align mounting plate with junction box mounting holes. | FIGURE 1 |
|
4.Gently pull household wires through center hole of mounting plate.
5.Secure mounting plate to junction box.
6.With a small wire connector, connect white wire from the CO alarm to white house- hold wire.
7.Connect black wire from the CO alarm to the black household wire.
8.For interconnecting CO alarms only:
•Use #18 AWG minimum solid or stranded wire. When interconnecting, maximum wire length between any two units is 1,500 feet for #18 AWG or 4,000 feet for #14 AWG (20 OHMS loop resistance.) See Figure 2.
WHITE | WHITE | WHITE |
|
BLUE | BLUE | TO NEUTRAL | |
BLACK | BLACK | BLACK |
|
|
| TO 120 | VAC (HOT) |
FIGURE 2
•This CO alarm may be interconnected
with as many as 11 other Firex CO alarms of the same model. DO NOT connect to any other type or model CO alarm or other device.
•Connect CO alarms to a single AC branch circuit. If local codes do not permit connection to a single AC branch circuit, be sure the neutral wire is common to all circuits used.
9.Plug wiring harness clip onto pins on the back of the unit.
10.Align tabs on back of base with slots on side of mounting plate. Slide base down to lock into position. See Figure 3.
11.Turn power on at the main fuse box or circuit breaker. The CO alarm will flash the red LED
and emit a short beep during its | FIGURE 3 | |
cycle. The green POWER light will stay on as | ||
| ||
long as the CO alarm is receiving AC power. |
|
4