TB14 SERIES GAS FRYERS

TB14 SERIES GAS FRYERS

CHAPTER 2: IMPORTANT INFORMATION

2.4Pre-Installation (cont.)

2.Frymaster TB14 Series gas fryers require 120VAC 60 cycle or 230VAC single-phase 50- hertz (International/CE) electrical service and are equipped with a 16-3 SJT grounded flexible power cord for a direct connection to the power supply. Amperage draw for each unit depends on the accessories supplied with the unit/system.

B.Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design- certified for the following installations:

1.Commercial installation only (not for household use).

2.Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch (13-cm) casters;

3.Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches (15-cm) rear, and equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch

(13-cm) casters.

2.4Pre-Installation (cont.) DANGER

Local building codes usually prohibit a fryer with its open tank of hot oil from being installed beside an open flame of any type, whether a broiler or the open burner of a range.

C. Installation Standards:

1. U.S. installations must meet:

2. Canadian installations must meet:

American National Standard Institute

CAN 1-B149 Installation Codes

ANSI Z83.11

Canadian Gas Association

American Gas Association

55 Scarsdale Road

8501 E. Pleasant Valley Road

Don Mills, ONT, M3B 2R3

Cleveland, OH 44131

 

National Electrical Code

Canadian Electric Code c22.1, part 1

ANSI/NFPA #70

Canadian Standards Association

American National Standard Institute

178 Rexdale Blvd.

1430 Broadway

Rexdale, ONT, M9W 1R3

New York, NY 10018

 

NFPA Standards #96 and #211

 

National Fire Protection Association

 

470 Atlantic Avenue

 

Boston, MA 02110

 

 

 

2-2

Page 10
Image 10
Frymaster Pre-Installation cont, TB14 SERIES GAS FRYERS IMPORTANT INFORMATION, C. Installation Standards, Danger