5.4.2 Filter Operation

TB14 SERIES GAS FRYERS

CHAPTER 5: BUILT-IN FILTRATION

5.4.2 Filter Operation

temperature [~350°F (~177°C)]. CAUTION

NEVER operate the filter unit unless cooking oil/shortening is at operating

temperature [~350°F (~177°C)].

1.Turn the fryer off. Ensure the filter pan assembly is prepared as described in Section 5.2.1– Assembling the Filter.

2.Remove fry baskets from frypot. Prior to filtering, skim any large debris from the shortening/oil. Use extreme caution, as shortening/oil is at or near operating temperature [~350°F (~177°C)].

Prior to filtering, skim any large debris from oil in frypot.

3.Remove the support grid from the frypot using the clean-out rod. Stir the oil with the L-shaped Teflon brush to suspend debris prior to draining.

Removing support grid from frypot prior to filtering.