Installation & Operation Manual
PARTS LIST INCLUDED
TB14 Series With Built-In Filtration
8195941
REQUIREMENTS in Chapter 3 of this manual for specifics
from slips or contact with the hot oil DANGER
other appliance DANGER
TABLE OF CONTENTS
TB14 Series Gas Fryers
Page #
TABLE OF CONTENTS CONT
1.1 After Purchase
1.3 Service Information
TB14 SERIES GAS FRYERS CHAPTER 1 INTRODUCTION
1.2 Ordering Parts
1.4 Computer Information cont
1.5 Safety Information
1.6 Service Personnel
TB14 SERIES GAS FRYERS CHAPTER 1 INTRODUCTION
B. Qualified Installation Personnel
C. Qualified Service Personnel
TB14 SERIES GAS FRYERS CHAPTER 1 INTRODUCTION 1.6.1 Definitions cont
2.1 Product Description
2.4 Pre-Installation
TB14 SERIES GAS FRYERS CHAPTER 2 IMPORTANT INFORMATION
2.2 Principles of Operation
2.4 Pre-Installation cont
C. Installation Standards
TB14 SERIES GAS FRYERS CHAPTER 2 IMPORTANT INFORMATION
2.6 Equipment Installed at High Altitudes
2.5 Air Supply and Ventilation
A. Do not connect this fryer to an exhaust duct
2.7 Receiving and Unpacking Equipment
If your equipment arrives damaged
3.2 Leveling the Fryer fryers equipped with legs only
TB14 SERIES GAS FRYERS CHAPTER 3 INSTALLATION
3.1 Installing the Fryer
movement to avoid damage and possible bodily injury DANGER
3.3 Installing Casters and Legs
TB14 SERIES GAS FRYERS CHAPTER 3 INSTALLATION
Questions? Call
3.4 Gas Connections
NATIONAL CODE REQUIREMENTS
Recommended Gas Supply Line Sizes
3.4 Gas Connections cont
½ PSI 3.45 kPa/35 mbar, a step-down regulator will be required
damage to the fryer’s gas piping and gas valves
new connections
injury may result
I. Flexible Couplings, Connectors and Casters
3.5 Electrical Connections
4.1.1 Pilot Lighting Procedures, Standing Pilot Only
TB14 SERIES GAS FRYERS CHAPTER 4 FRYER OPERATIONS
4.1 Initial Start-up
4.1.1 Pilot Lighting Procedures, Standing Pilot Only cont
TB14 SERIES GAS FRYERS CHAPTER 4 FRYER OPERATIONS
4.2 Boil-Out Procedure
4.3 Final Preparation
4.2 Boil-Out Procedure cont
so will damage the heating tubes and frypot, and void the warranty
crack glass containers
TB14 SERIES GAS FRYERS CHAPTER 5 BUILT-IN FILTRATION
transfer
5.1 General
TB14 SERIES GAS FRYERS CHAPTER 5 BUILT-IN FILTRATION
5.2 Filtration Preparation
5.2.1 Assembling the Filter
5.2.1 Assembling the Filter cont
Assemble the filter as follows
4. Sprinkle 8 ounces of filter powder on the filter sheet. Ensure the powder covers the filter paper evenly
5.2.2 Installing the Filter
5.3 Daily Filtration Operation
5.3.1 General Overview
5.4 Operating the Filter
5.3.2 Filtering Tools
container for disposal
above the maximum fill line located on the container DANGER
5.4 Operating the Filter cont
overflow and spillage of hot oil/shortening DANGER
shortening will rush out creating the potential for severe burns
5.4.2 Filter Operation
temperature ~350F ~177C
1. Turn the fryer off. Ensure the filter pan assembly is prepared as described in Section 5.2.1- Assembling the Filter
5.4.2 Filter Operation cont
5-10
5-11
5-12
5-13
DO NOT ALLOW CRUMBS TO ACCUMULATE IN TRAY
water. NEVER allow water to enter the Filtration System
TB14 SERIES GAS FRYERS CHAPTER 6 COMPUTER OPERATION
6.1 Operating Fryers with Computer Magic III.5 Computers
DESCRIPTION
TB14 SERIES GAS FRYERS CHAPTER 6 COMPUTER OPERATION
6.1.1 Equipment Setup and Shutdown Procedures
Setup
Shutdown
6.1.1 Equipment Setup and Shutdown Procedures cont
Do not cancel the melt cycle mode if using solid shortening
results, do not cook product until the display reads
6.2 Programming the Computer Magic III.5 Computer
6.1.2 Checking Temperature
6.2.1 Boil Feature
6.2 Programming the Computer Magic III.5 Computer cont
6.2.2 Temperature Selection-Fahrenheit to Celsius
6.2.1 Boil Feature cont
SEE CHAPTER 4.2 FOR ADDITIONAL BOIL-OUT PROCEDURES
6.2.3 Constant Oil Temperature Display Mode
7.1 General
TB14 SERIES GAS FRYERS CHAPTER 7 PREVENTATIVE MAINTENANCE
time the cleaner remains on the food-contact surfaces
7.2 Daily
TB14 SERIES GAS FRYERS CHAPTER 7 PREVENTATIVE MAINTENANCE
7.4 Periodic/Annual
Built-in Filtration
Built-in Filtration cont
7.4 Periodic/Annual cont
7.5 Stainless Steel Care
burns
Disconnect all power cords before servicing
TB14 SERIES GAS FRYERS CHAPTER 8 TROUBLESHOOTING
tests are required. Use extreme care when performing such tests
authorized service agent only
TB14 SERIES GAS FRYERS CHAPTER 8 TROUBLESHOOTING
8.2 Pilot Burner Malfunction cont
8.3 Main Burner Malfunctions
8.3 Main Burner Malfunctions cont
8.4.1
Wiring
Diagrams
TB14 Series
8.4.2 TB14 Series Interface Board Enlarged View
Dual Operation Only
Terminal #2 - Medium
PART #
TB14 SERIES GAS FRYERS CHAPTER 9 PARTS LIST
9.1 Accessories
COMPONENT
TB14 SERIES GAS FRYERS CHAPTER 9 PARTS LIST
9.2 Cabinetry and Related Components
9.2 Cabinetry and Related Components cont
1 823-3248 Support, Leg- Without Optional SUFF Filter Only
9.3 Computer and Related Components
9.4 Filter Module Components
To Frypot
To Filter
9.4 Filter Module Components cont
9.5 Filter Pan Components
9.6 Frypot, Burners and Related Components
9.6 Frypot, Burners and Related Components cont
9.7 Oil Return Components
FAX Parts 1-318-219-7140 FAX Tech Support
SERVICE HOTLINE
Shipping Address 8700 Line Avenue, Shreveport, Louisiana
Price $10.00