First Alert FA145C user manual Quick Guide to System Functions, Function Procedure Comments

Models: FA145C

1 44
Download 44 pages 2.52 Kb
Page 33
Image 33

QUICK GUIDE TO SYSTEM FUNCTIONS

FUNCTION

PROCEDURE

COMMENTS

Check Zones

Press READY key.

To view faulted zones when system not ready.

Arm System

Enter code. Press arming key desired:

Arms system in mode selected.

 

(AWAY, STAY, INSTANT, MAXIMUM)

 

 

 

 

Quick Arm

Press #. Press arming key desired:

Arms system in mode selected, quickly and without use of code.

(if programmed)

(AWAY, STAY, INSTANT, MAXIMUM)

 

Bypass Zone(s)

Enter code. Press BYPASS key.

Bypassed zones are unprotected and will not cause an alarm if

 

Enter zone number(s) to be bypassed

violated.

 

(use 2-digit entries).

 

Quick Bypass

Enter code. Press BYPASS key.

Bypasses all faulted zones au tomatically.

(if programmed)

 

 

Silence Sounders

Enter code. Press OFF key.

Also disarms system. Memory of alarm remains until cleared.

Burglary:

Fire:

Press OFF key.

Memory of Alarm remains until cleared.

"Check":

Press any key.

Determine cause. See Page 26.

 

 

 

Disarm System

Enter code. Press OFF key.

Also silences sounders. Memory of alarm remains until cleared.

Clear Alarm Memory

After disarming, enter code again.

Keypad will beep rapidly upon entry if alarm has occurred.

 

Press OFF key again.

Alarm display will remain upon disarming until cleared.

Duress (if active)

Arm or disarm "normally", but

Performs desired action and sends silent alarm to central station.

 

use your 4-digit Duress code to do so.

 

Panic Alarms

Press key [A], [B], or [C] for at least 2 sec., or

See Page 23 for panic functions programmed for your system.

(as programmed)

(if no A, B, or C on your keypad),

 

 

press keys [1] & [], or [ ] & [#], or [3] & [#],

 

 

both at same time.

 

Chime Mode

To turn ON or OFF: Enter code. Press CHIME key.

Keypad will sound if doors or windows are violated while system is

 

 

disarmed and chime mode is ON.

Test Mode

To turn ON: Enter code. Press TEST key.

Tests alarm sounder and allows sensors to be tested.

 

To turn OFF: Enter code. Press OFF key.

 

 

 

 

Phone Access

Consult Phone Access User's Guidethat

Permits system access remotely, via Touch-tone phone

(Phone Module)

accompanies Phone Module.

(see pages 4, 11).

if applicable

 

 

Service Request

Press key “D” (if present,) for 2 secs, or press

Sends a “Request for Service” message to the central station (if

 

[] & [#] keys simultaneously. (See page 23.)

connected). See page 23 to see if [] & [#] keys provide this feature.

 

 

 

– 33 –

Page 33
Image 33
First Alert FA145C user manual Quick Guide to System Functions, Function Procedure Comments

FA145C specifications

The First Alert FA145C is an innovative smoke and carbon monoxide detector designed to enhance safety in residential settings. This intelligent device combines advanced technology with user-friendly features, ensuring that homeowners can protect their families from fire and toxic gas threats effectively.

At the core of the FA145C is its dual-sensor technology, which utilizes both photoelectric and ionization sensors. The photoelectric sensor excels at detecting smoldering fires, often caused by burning materials like mattresses and upholstery, while the ionization sensor is highly effective in identifying flaming fires, such as those ignited by paper or flammable liquids. This combination results in faster response times to a wider range of fire types, significantly increasing safety within the home.

The FA145C also features a built-in carbon monoxide detector, providing an added layer of protection against this odorless and colorless gas. Carbon monoxide is a byproduct of burning fossil fuels, and exposure can lead to serious health hazards. The incorporation of CO detection in one device simplifies the safety measures in a home and ensures comprehensive monitoring.

A standout feature of the First Alert FA145C is its voice alert system. This system provides clear announcements, indicating whether smoke or carbon monoxide has been detected. By minimizing confusion during emergencies, the voice alerts allow for quicker and more informed reactions, particularly in a panic-inducing situation.

The unit is equipped with a 10-year battery life, which reduces the hassle and costs associated with frequent replacements. The long-lasting battery ensures that the device remains operational for an extended period, contributing to peace of mind for homeowners. Additionally, the FA145C includes a convenient battery status indicator, alerting users when the battery is running low.

Installation is straightforward, thanks to the user-friendly design and included mounting hardware. The sleek, modern appearance of the FA145C allows it to blend seamlessly with various interior styles, making it a practical choice for any home.

Overall, the First Alert FA145C stands out as a crucial safety tool, integrating advanced sensors, voice alerts, and long battery life into a single device. This smoke and carbon monoxide detector sets a high standard for residential safety, offering homeowners both reassurance and protection against potential hazards.