SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS
| (ALPHA DISPLAY KEYPADS) | ||||
SOUND | CAUSE | DISPLAY |
|
| |
LOUD, INTERRUPTED* | FIRE ALARM | FIRE is displayed; descriptor of zone in alarm is displayed. | |||
Keypad & Ext. Sounder |
|
|
|
| |
LOUD, CONTINUOUS* | BURGLARY/AUDIBLE | ALARM is displayed; descriptor of zone in alarm is also displayed.. | |||
Keypad & Ext. Sounder | EMERGENCY ALARM | Also see "Exit Alarm Warning Displays and Sounds" on page 21. | |||
ONE SHORT BEEP | a. SYSTEM DISARM | a. DISARMED/READY TO ARM | is displayed. Green READY indicator (if present) is lit. | ||
(not repeated) | b. SYSTEM ARMING ATTEMPT | b. The number and descriptor of the open protection zone is displayed. | |||
Keypad only | WITH AN OPEN ZONE | Green READY indicator (if present) is not lit. | |||
| c. BYPASS VERIFY | c. Numbers and descriptors of the bypassed protection zones are displayed (One beep | |||
|
| is heard for each zone displayed). Subsequently, the following is displayed: | |||
|
| DISARMED BYPASS Ready to Arm | |||
ONE SHORT BEEP | SYSTEM IS IN TEST MODE | Opened Zone identifications will appear. | |||
every 40 secs. |
|
|
|
| |
Keypad only |
|
|
|
| |
ONE BEEP | a. LOW BATTERY AT A XMTR | a. LO BAT displayed with description of transmitter. | |||
every 40 sec. | b. SYSTEM MAIN BATT. WEAK | b. LO BAT displayed with no transmitter description. | |||
Keypad only | |||||
c. TROUBLE | c. CHECK displayed. Descriptor of troubled protection zone is displayed. | ||||
| |||||
TWO SHORT BEEPS | ARM AWAY OR MAXIMUM | ARMED AWAY | or ARMED MAXIMUM is displayed. Red ARMED indicator is lit. | ||
Keypad only |
|
|
|
| |
THREE SHORT BEEPS | a. ARM STAY OR INSTANT | a. ARMED STAY or ARMED INSTANT is displayed. Red ARMED indicator is lit. | |||
Keypad only | b. ZONE OPENED WHILE SYS - | b. CHIME displayed. Pressing | ✱/ READY key will display descriptor of opened zone. | ||
| |||||
| TEM IS IN CHIME MODE |
|
|
| |
| c. ZONE OPENED WHILE SYS- | c. Open protection zone descriptor is displayed. | |||
| TEM IS IN TEST MODE |
|
|
| |
RAPID BEEPING | MEMORY OF ALARM | FIRE or ALARM | is displayed; descriptor of zone in alarm is displayed. | ||
Keypad only |
|
|
|
| |
SLOW BEEPING | a. ENTRY DELAY WARNING | a. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. Exceeding the delay time | |||
Keypad only |
| without disarming causes alarm. | |||
| b. EXIT DELAY ALERT | b. ARMED AWAY or ARMED MAXIMUM is displayed. Slow beeps change to fast | |||
| (if programmed) | beeps during last 5 seconds of exit delay. |
*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is a steady ring. Note: Also see Other Trouble Displays and Total Power Failure under TROUBLE CONDITIONS on pages 27 and 28.