First Alert FA168CPSSIA manual About The Keypads Continued, Alarm, Fixed-WordDisplay Keypad, Stay

Models: FA148CPSIA FA168CPSSIA

1 64
Download 64 pages 59.73 Kb
Page 9
Image 9
About The Keypads (Continued)

About The Keypads (Continued)

Fixed-Word Display Keypad

AWAY:

All burglary zones, interior and

 

 

 

 

 

 

 

 

 

AWAY NIGHT NO AC

 

perimeter, are armed.

 

 

 

 

 

 

 

BYPASS

PHONE TEST

STAY:

Perimeter burglary zones, such as

 

 

 

NOT READY

 

 

 

STAY

ALARM

CHIME BAT

 

protected windows and doors, are

FIRE CHECK INSTANT

CANCELED

 

armed.

 

 

 

FA260KP

 

INSTANT:

Entry delay is turned off:

 

 

 

AWAY

 

NO AC

 

 

 

 

 

 

 

Lit with STAY = Instant mode

 

 

 

STAY

 

CHIME

 

Lit with AWAY = Maximum mode

 

ALARM

INSTANT

 

BAT

 

 

CHECK BYPASS

CANCELED

BYPASS: This appears when one or more

 

FIRE

NIGHT

NOT READY

 

 

 

FA215KP

 

 

burglary protection zones have been

 

 

 

 

 

bypassed.

 

FIXED-WORD DISPLAYS

NOT READY:

Appears when burglary portion of the system is not ready for arming

 

(due to open protection zones). The system is ready to arm when this

 

message disappears and the READY indicator light comes on.

 

NO AC:

Appears when AC power has been cut off. System is operating on

 

backup battery power.

 

 

 

 

 

 

AC:

Appears when AC power is present.

 

 

 

 

 

 

CHIME:

Appears when the CHIME feature is activated.

 

 

 

BAT:

Low battery condition in a wireless sensor (if zone number displayed)

 

or low system battery (if no zone number displayed).

 

 

 

ALARM:

Appears when an intrusion has been detected and the system is armed

 

(also appears during a fire alarm or audible emergency alarm).

 

Accompanied by the protection zone in alarm.

 

 

 

CHECK:

Appears when a malfunction is discovered in the system at any time or

 

if an open is detected in a FIRE zone at any time or a fault in a

 

DAY/NIGHT burglary zone during a disarmed period. Accompanied by

 

a display of zone number in trouble.

 

 

 

 

 

 

FIRE:

Appears when a fire alarm is present. Accompanied by a display of the

 

zone in alarm.

 

 

 

 

 

 

 

A FIRE display also appears when a fire alarm is manually activated,

 

accompanied by a display of emergency key zone number programmed

 

for fire.

 

 

 

 

 

 

NIGHT:

Appears with “STAY” when the system is armed in Night-Stay mode

 

(perimeter burglary zones and pre-selected interior zones are armed).

CANCELED:

Appears when an alarm has been canceled (see Exit Alarm section on

 

page 13 for more information on canceled alarms and displays).