$UPLQJ￿WKH￿6\VWHP

6WD\￿0RGH￿￿$UPV￿3HULPHWHU￿2QO\￿￿(QWU\￿'HOD\￿2Q

Used when you want to arm the system with persons staying inside (or if you have pets that are moving throughout the premises).

The perimeter sensors are armed, but interior sensors are left disarmed.

Exit delay begins (you can leave through the entry/exit door, if desired).

An alarm sounds if any protected window or non-entry/exit door is opened.

You may otherwise move freely within the premises.

Persons entering later can enter through an entry/exit door, but they must disarm the system within the entry delay period to avoid sounding an alarm.

1LJKW￿6WD\￿0RGH￿￿$UPV￿3HULPHWHU￿2QO\￿￿3OXV￿6HOHFWHG￿=RQHV

Use Night-Stay mode to provide increased security while staying inside.

Arms same as Stay mode, but also arms pre-selected interior sensors (programmed by your installer), while other interior sensors are left disarmed.

Persons entering later can use an entry/exit door but must not violate any of the programmed interior zones to avoid sounding an alarm.

IMPORTANT: When Night-Stay mode is on, the selected interior zones are armed and cause an alarm if anyone enters those areas (e.g., waking in the middle of the night). To avoid sounding an alarm, you must disarm the system before any activity takes place in those interior zones.

,QVWDQW￿0RGH￿￿$UPV￿3HULPHWHU￿2QO\￿￿(QWU\￿'HOD\￿2II

Used when staying inside and do not expect anyone to use an entry/exit door.

Arms same as Stay mode.

An alarm sounds immediately if any protected perimeter window or any door is opened, including entry/exit doors.

IMPORTANT: Arming in this mode greatly increases the chance of false alarms. Use extreme care in selecting this mode of arming.

$ZD\￿0RGH￿￿$UPV￿(QWLUH￿6\VWHP￿￿(QWU\￿'HOD\￿2Q

Used when nobody will be staying inside (including pets).

The entire system (interior and perimeter) is armed.

Exit delay begins letting you leave through the entry/exit door.

An alarm sounds if a protected window or any door is opened, or if any movement is detected inside your premises.

You can reenter through an entry/exit door, but you must disarm the system within the entry delay period to avoid sounding an alarm.

0D[LPXP￿0RGH￿￿$UPV￿(QWLUH￿6\VWHP￿￿(QWU\￿'HOD\￿2II

Used when leaving the premises for extended periods (e.g., vacation).

Arms same as Away mode, but entry delay is off.

An alarm sounds same as Away mode, and sounds upon opening entry/exit doors.

– 14 –

Page 14
Image 14
First Alert FA148CP-CN, FA168C-CN manual $UPLQJWKH6\VWHP

FA168C-CN, FA148CP, FA168C, FA148CP-CN specifications

The First Alert FA168CP-CN, FA168C-CN, FA168C, and FA168CP are standout models in the realm of fire alarm technology, presenting an effective blend of advanced features, reliable performance, and user-friendly design.

A hallmark of these models is their dual-sensor technology, which combines both photoelectric and ionization sensors. This innovative approach allows for quicker detection of a wide range of fire types, from smoldering fires that typically produce more smoke to fast-flaming fires that generate more heat. This dual capability enhances the efficiency and response time of the alarm, ensuring users receive timely alerts.

Another prominent characteristic of these First Alert models is their comprehensive connectivity. Most models are equipped with a wireless interconnect feature, which allows multiple alarms throughout the home to communicate with one another. When one unit detects smoke or carbon monoxide, all interconnected alarms will sound, maximizing alertness across the property. This feature is particularly beneficial in larger homes or multi-story buildings, where sound may not travel freely.

The FA168 series also includes a built-in, non-replaceable lithium battery, providing up to 10 years of power. This design not only eliminates the need for constant battery replacements but also ensures that the unit remains functional for an extended period without hassle. A convenient low battery notification alerts users when it’s time to replace the entire unit, adding an extra layer of safety.

In terms of installation, these models offer a user-friendly design that makes setup and maintenance straightforward. The unit typically features a single test/silence button, allowing users to quickly test the alarm's functionality or silence false alarms with ease.

Furthermore, the clear LED indicators provide visual confirmation of the alarm status, keeping users informed about potential threats. Design-wise, the FA168 series models boast a sleek and modern aesthetic that can seamlessly blend into various interior environments.

Overall, the First Alert FA168CP-CN, FA168C-CN, FA168C, and FA168CP serve as reliable guardians against fire hazards, employing cutting-edge technology to offer peace of mind to users. With their formidable features, easy installation, and efficient power management, these fire alarm models stand as excellent choices for both homes and businesses seeking enhanced safety measures.