3DJLQJ￿)HDWXUH

$ERXW￿$XWRPDWLF￿3DJLQJ

Your system may be set up to automatically send alert messages to several pagers (up to four for FA168C, up to two for FA148CP) as certain conditions occur in your system.

The following events can be programmed by your installer to be sent to the pagers: arming and disarming, alarms, and trouble conditions. (reports when arming/disarming from a keypad using a security code; auto-arming/disarming, arming with assigned button, and keyswitch arming do not send pager messages.)

You can also program the system to send an automatic pager message to alert you in the event that someone has not arrived home (disarmed the system) within a defined period of time (see the Scheduling section for details on programming a “latch key report”).

Your installer programs the pager phone numbers and reporting events.

The pager message consists of a 7-digit system status code that indicates the type of condition that has occurred.

An optional, predefined 16-digit character string can precede the 7-digit system status code; these characters can consist of a PIN no., subscriber account no., or any additional data that you may wish to have sent to the pager.

The pager display format is as follows:

 

 

 

 

 

 

 

 

3-digit Event Code

 

 

Optional 16 digits

￿AAAAAAAAAAAAAAAA

 

 

 

BBB

CCCC

￿4-digit User or Zone No.

 

 

 

 

 

 

 

 

 

 

 

 

A =

 

 

 

B =

 

 

 

 

 

C =

 

Optional 16-digits for

 

A 3-digit code that

 

A 4-digit User or Zone number, depending on the type of

 

 

event that has occurred, where:

 

Account numbers,

 

 

describes the event

 

 

 

 

 

alarms and troubles display zone number

PIN numbers, or any

 

that has occurred

 

 

 

arming/disarming (opens/closes) display user number

other data;

 

 

in your system

 

programmed by the

 

 

(see for event

 

The first 2 digits are always “00” (e.g., 0004 represents

installer, if required.

 

codes table below)

 

zone or user number 4), and, single-digit user or zone

 

 

 

 

 

 

numbers are always preceded by a zero.

The 3-digit Event Codes (BBB) that can be displayed are:

 

 

911 =

 

 

 

811 =

 

 

 

 

 

101 =

 

102 =

Alarms.

 

 

 

Troubles.

 

 

 

 

Open

 

Close

The 4-digit number

 

 

 

The 4-digit number

 

 

 

(system disarmed).

(system armed).

(CCCC) following this

 

(CCCC) following this

 

The 4-digit number

 

The 4-digit number

code is the zone number

 

code is the zone number

 

(CCCC) that follows

 

(CCCC) that follows

that has caused the

 

 

 

that has caused the

 

 

 

this code is the user

 

this code is the user

alarm.

 

 

 

trouble.

 

 

 

number that has

 

number that has armed

 

 

 

 

 

 

 

 

 

disarmed the system.

the system.

Examples of typical 7-digit pager displays follow.

Ex. 1.= Reporting of an alarm (911) caused by a fault on zone 4 (0004).

Ex. 2.

￿￿￿￿￿￿￿

= Reporting of a closing–system arming (102)– by user 5 (0005).

– 26 –

Page 26
Image 26
First Alert FA148CP-CN, FA168C-CN manual 3DJLQJHDWXUH, $ERXW$XWRPDWLF3DJLQJ

FA168C-CN, FA148CP, FA168C, FA148CP-CN specifications

The First Alert FA168CP-CN, FA168C-CN, FA168C, and FA168CP are standout models in the realm of fire alarm technology, presenting an effective blend of advanced features, reliable performance, and user-friendly design.

A hallmark of these models is their dual-sensor technology, which combines both photoelectric and ionization sensors. This innovative approach allows for quicker detection of a wide range of fire types, from smoldering fires that typically produce more smoke to fast-flaming fires that generate more heat. This dual capability enhances the efficiency and response time of the alarm, ensuring users receive timely alerts.

Another prominent characteristic of these First Alert models is their comprehensive connectivity. Most models are equipped with a wireless interconnect feature, which allows multiple alarms throughout the home to communicate with one another. When one unit detects smoke or carbon monoxide, all interconnected alarms will sound, maximizing alertness across the property. This feature is particularly beneficial in larger homes or multi-story buildings, where sound may not travel freely.

The FA168 series also includes a built-in, non-replaceable lithium battery, providing up to 10 years of power. This design not only eliminates the need for constant battery replacements but also ensures that the unit remains functional for an extended period without hassle. A convenient low battery notification alerts users when it’s time to replace the entire unit, adding an extra layer of safety.

In terms of installation, these models offer a user-friendly design that makes setup and maintenance straightforward. The unit typically features a single test/silence button, allowing users to quickly test the alarm's functionality or silence false alarms with ease.

Furthermore, the clear LED indicators provide visual confirmation of the alarm status, keeping users informed about potential threats. Design-wise, the FA168 series models boast a sleek and modern aesthetic that can seamlessly blend into various interior environments.

Overall, the First Alert FA168CP-CN, FA168C-CN, FA168C, and FA168CP serve as reliable guardians against fire hazards, employing cutting-edge technology to offer peace of mind to users. With their formidable features, easy installation, and efficient power management, these fire alarm models stand as excellent choices for both homes and businesses seeking enhanced safety measures.