INSTALLATION

LOCATING GRILL/BUILT-IN CLEARANCES

Clearances to Non-Combustible Construction*:

A minimum of 76 mm clearance from the back of the grill to non-combustible construction is required for the purpose of allowing the hood to open fully. It is desirable to allow at least 153 mm rear and side clearance to non-combustible construction above the cooking surface for counter space. If you’ll be using the rotisserie op- tion, the space is essential for motor and skewer clearance. The grill can be placed directly adjacent to non-com- bustible construction below the cooking surface. (Fig. 8)

Clearances to Non-Combustible Construction*

Min. 115mm

BGB 48 BQAR = 1378 mm BGB 48 BQR = 1382 mm BGB 36 BQAR = 1082 mm

(with rotisserie motor mounted)

BGB 48 Models = 1216 mm BGB 36 Models = 911 mm

(without rotisserie motor mounted)

673 mm

rotisserie motor

616 mm

grill

exhaust

76 mm (to non-combustible construction / minimum hood clearance)

 

267 mm

Bottom of

 

 

support flange

254 mm

 

 

 

 

 

 

51 mm

562 mm

 

centre of gas inlet 81 mm

centre of gas inlet

 

 

559 mm

 

 

 

 

 

 

648 mm

 

FIG. 8

WARNING!

Failure to maintain required clearances creates a fire hazard that may result in property damage or serious personal injury. We recommend installing the Grill as far away from combustible surfaces as possible.

WARNING!

The BGB Grill is designed to function in an open area. Recommended minimum clearances should be maintained to all surfaces (combustible and noncombustible) for optimum performance. Noncombustible material within the minimum clearance area could result in discoloration or deterioration.

WARNING!

If a noncombustible material such as stucco is covering a combustible material such as wood, the minimum clear- ance distance needs to be held to the wood. The presence of a noncombustible material inside the clearance zone does not eliminate the minimum clearance zone to combustible material.

*DEFINITION OF NONCOMBUSTIBLE MATERIAL - Material which is not capable of being ignited and burned, such as materials consisting entirely of, or a combination of, steel, iron, brick tile, concrete, slate, and plaster.

Clearances to Combustible Construction**:

Minimum of 310 mm from the sides and rear of grill must be maintained to adjacent vertical combustible con- struction, above the counter top level. You should take in account that there is a large volume of heat, and smoke will exhaust from the rear of the grill. This may discolour or damage unprotected areas (Fig. 04). Do not install under unprotected combustible construction without using a fire safe ventilation system.

A 310 mm minimum clearance must be maintained under the counter top to combustible construction. The clear- ance can be modified by a use of an insulated jacket.

10

Page 12
Image 12
Fisher & Paykel BGB36, BGB48 installation instructions Clearances to Non-Combustible Construction