INSTALLATION
GAS HOOK-UP
GAS REQUIREMENTS
Verify the type of gas supply to be used, either natural or LPG, by checking the gas type label on rear panel of the unit and the serial label behind the drip pan handle on the
If the unit is being connected to a reticulated gas supply, an
All pipe sealants must be an approved type and resistant to the actions of LPG gases. Never use pipe sealant on flare fittings. All gas connections should be made by a qualified gas fitter and in accordance with local codes and ordinances. In the absence of local codes, the installation must comply with the the requirements of AS/ NZS 5601.1:2010 and any other applicable statutory regulations. Gas conversion kits are available from Customer Care. See section ‘Service’ for contact details. When ordering gas conversion kits, have the model number, and the type of gas (natural or LPG) from your grill.
The appliance and its individual
NATURAL GAS HOOK UP:
Important!
THIS TYPE OF CONNECTION SHOULD BE PERFORMED BY A CERTIFIED OR LICENSED GAS FITTER ONLY.
Connection: Grills set for use with Natural gas come with an NG regulator assembly which has a short section of hose already connected. The regulator has a test point. The regulator assembly is not connected to the appliance. A certified gas fitter needs to connect the appliance to the gas supply.
For built-in installation with connection to Natural Gas:
1.Attach regulator hose assembly to the appliance using the 3/8” SAE 45 Flare connection.
2.Plumb from the female 1/2” BSP side of the regulator to gas supply.
3.Do leak test.
4.After the connection is completed, turn the
For units mounted on a mobile cart and being connected to a reticulated supply of Natural gas: a special ‘quick connect’ flexible hose accessory kit must be purchased separately by the installer from DCS by Fisher & Paykel. See section ‘Service’ for contact details.
1.Purchase, upon request from the customer, the ‘quick connect’ flexible hose accessory kit - 1/2” BSP connec- tion (for the regulator) and a quick disconnect flexible hose (for connection to house supply).
2.If not already done, attach the regulator (1kPa) hose assembly to the appliance using the 3/8” SAE 45 Flare con- nection.
3.Thread the
4.Do leak test.
5.After the connection is completed, turn the
6. Disconnect hose, then coil up hose and hang on exterior hook at the back of the cart.
13