Fisher & Paykel CG603 Installation Instructions, Gas Supply Connection Check, Natural Gas, LP Gas

Models: CG603

1 8
Download 8 pages 42.77 Kb
Page 6
Image 6
Installation Instructions
10 To refit the CG913 series hob tray, repeat steps 6 and 7 in reverse.
11 Check insulation resistance and earth
continuity.continued...
Reset the venturi (see fig.2). Loosen the venturi screw, move the venturi toward the orifice approx. 2 mm.
9
Replace the wok orifice with the correct one using a 10 mm spanner.
8
Lift hob tray from the product.
WARNING!
Cut Hazard.
Beware of sharp edges.
7
6 Remove the 2 screws holding each burner (3 on the wok burner).
Pull off knobs.
Remove all trivets and burner heads.
Ensure all gas valves are turned off.
2
3
4
5 Unscrew the orifices and replace them with the correct ones. (size numbers are stamped on the side, eg. 70= 0.70 mm) (see figure 1)
Turn off the main electrical supply.
WARNING!
Electrical Shock Hazard.
Disconnect product from main power supply before continuing.
1
The operation of the appliance, including the ignition system, must be tested before installation is complete.
If after following the instructions given, satisfactory performance cannot be obtained, contact the local gas authority or your local Approved Service Agent for advice and assistance.
Conversion to Different Gas Type
Burners can be used with NG or LPG, provided that the orifices appropriate for the gas supply are installed.
To change the orifices, you will need a 7 mm box spanner (and a 10 mm ring spanner for CG913TM).

Installation Instructions

Natural Gas

For Natural Gas usage the gas supply is connected to the regulator which is supplied loose with a built in test point - 1kPa (4” WG) and the inlet connection of 1/2 “ B.S.P. (male thread). Do not over tighten.

The test point pressure should be preset to 1.0 kPa with the wok and semi - rapid burners operating at maximum.

LP Gas

For LPG usage the gas supply for the appliance must be regulated to a pressure of 2.75kPa (11” WG). See ‘Conversion to a different gas type’ .

Gas Supply Connection Check

The connection point shall be accessible with the appliance installed.

To enable the gas supply to be readily shut off, the gas supply must be connected with an isolating valve close to the product.

After installation and making all connections check thoroughly for possible leaks.

1 Turn all control knobs on the unit to “off” position.

2 Open the valve on the gas supply.

3 Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a time by brushing the solution over the connection.

4 The presence of bubbles will indicate a leak. Tighten the fitting and recheck for leaks. Ensure the washer (supplied) is located between elbow and product gas inlet.

5 Turn on each gas valve and light each burner.

6 Check for a clear blue flame without yellow tipping. If burners show any abnormalities, check that they are located and assembled properly. Check correct orifices are installed.