Maximum Length of Exhaust Duct

Maximum length of 100mm diameter duct with 100mm hood.

Number of 90˚

Rigid

Thick Wall Flexible Metal

elbows/bends

(fully extended)

 

 

 

 

0

19.5m

10.9m

 

 

 

1

16.5m

9.4m

 

 

 

2

13.4m

8.2m

 

 

 

3

10.6m

7.6m

 

 

 

4

8.2m

7.0m

For exhaust systems not covered by the exhaust duct length charts (such as multiple unit hook- ups, plenums, and power-assist fans), contact our Customer Care Centre as on page 35.

Alternative Installation for Close Clearances

Venting systems come in many varieties. Select the type best for your installation. A typical close-clearance installation is shown.

 

swivel collar

sections separate,

wall connection

 

fittings can face

 

same or opposite

 

swivel collar

telescoping

sections

 

Extra long

 

band–clamp

beveled edges

for dryer

allow corner

connection

installations

 

The Maximum length using a 50mm x 150mm duct with two elbows and a 65mm exhaust hood is 2.4 metres.

Refer to the venting system kit manufacturers instructions.

12

Page 12
Image 12
Fisher & Paykel DEIX1 Alternative Installation for Close Clearances, Maximum length of 100mm diameter duct with 100mm hood