18Installation instructions

Connecting the power supply cable

To connect the power supply cable to the cooker:

1Remove the four screws that hold shield “A” behind the cooker.

2Open the cable clamp “D” completely.

3 Check the position of the U bolts on the terminal block “B” (Fig. 16a) corresponds to the connection diagrams in Fig. 16b and Fig. 16c.

4 Insert the power supply cable into the cable clamp “D” and into the cable protector

“C”. The supply cable must be of a suitable size for the current requirements of the

appliance.

This cooker must be connected to the power supply using V105 insulated cable. This cooker must be earthed.

5Connect the phase and earth cables to terminal “B” according to Figs. 16b and 16c.

6Tighten the power supply cable and fix it with the cable clamp “D”.

7Re-mount shield “A”, securing it tightly with the four screws.

Note: the earth conductor must be left about 30 mm longer than the others.

Power supply

220 - 240V ~ 5300W 50Hz

B

C

DA

Fig. 16a Accessing the terminal block

1

2

3

4

5

 

L1

 

 

N(L2)

PE

 

Redd oror

 

 

 

 

 

Brownn

 

 

 

GreenG een

e)

 

 

 

(Live)

 

 

 

and

Blackk or

 

 

Yellow

 

 

(

rth)

Blue

 

 

(Earth)

or Blue

 

 

 

(

utral)

 

 

 

(Neutral)

 

 

 

Fig. 16b Electrical connection

220-240 V

1

2

3

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1 N (L2) PE

PE

 

 

 

 

 

Earth

 

 

 

 

 

NNeutral

LLive

Fig. 16c Connection diagram